Triplett LazerTape 160 Скачать руководство пользователя страница 14

LazerTape 160 Users Manual

Indirect Measurement - Determining a Distance Using 3 Measurements

(

See Figure H

)

Press this button

twice; the display shows the double pythagoren

symbol

. The distance to be measured (1) flashes in the symbol.

Aim at point (1) and trigger the measurement. After the first

measurement, point at (2), establishing a right angle.

Press to measure point (2). Aim laser at point (3)

Press to measure point (3).

The total height is displayed on the 3rd line.

Historical Storage

Press to review the previous 20 records. Press button repeatedly to cycle

through the memory, or use

or

buttons to navigate through the

records.

All of the records can be cleared by pressing the Memory and Clear buttons

simultaneously.

14

3

2

1

Figure H

Содержание LazerTape 160

Страница 1: ...TRIPLETT LazerTape 160 Lazer Distance Meter Instruction Manual 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Страница 2: ...LazerTape 160 Users Manual...

Страница 3: ...______________________________ 20 The Triplett LazerTape 160 is a compact feature loaded Laser Distance Meter specifically designed for indoor applications With it one person can measure distance in s...

Страница 4: ...his instrument Do not open this instrument There are no user serviceable parts inside Do not remove warning labels from this instrument Do not point the laser into anyone s eyes including your own Do...

Страница 5: ...wards other people Although the laser is low power and is usually harmless it should never be purposely directed into anyone s eyes WARNING Looking directly into the laser with magnifying lenses e g b...

Страница 6: ...n this symbol appears permanently in the display Use alkaline batteries only Remove the batteries if the unit is unused for several weeks or longer Keypad See Figure B Figure A 1 ON MEASURE button 2 A...

Страница 7: ...s Area measurement Volume measurement Indirect measurement Indirect second measurement 5 Single measurement 6 Battery status 7 Memory memories used memory selected 8 Error symbol 9 Continuous MAX MIN...

Страница 8: ...ncel the last action or to clear the data display To clear the memories press the Memory button and Clear Off button simultaneously Reference Location See Figure D The default Reference Location is fr...

Страница 9: ...urn the backlite on or off The backlite will turn off automatically in 30 seconds Units of measure Press and hold this button for several seconds then release to change the measuring UNITS 9 Test Equi...

Страница 10: ...used to find a specific distance from a target When activated a series of 100 measurements is tak en e ve ry 0 5 sec ond s the la te s t be in g d isp laye d on the 3r d line 12 o f the LC D Th e MA X...

Страница 11: ...ent Press to cancel the last operation Press to return to Single Measurement mode Area Measurement Press th e A r e a V o lu m e b u tt o n once The symbol appears in the display Press button to take...

Страница 12: ...asurement appears in the display Press to take the first distance measurement i e length Press to take the second distance measurement i e width Area displays on the 3rd line Press to take the third d...

Страница 13: ...indirect measurements Press this button once the display shows The distance to be measured 1 flashes in the symbol Aim at the upper point 1 and trigger the measurement After measurement 1 move the La...

Страница 14: ...asurement After the first measurement point at 2 establishing a right angle Press to measure point 2 Aim laser at point 3 Press to measure point 3 The total height is displayed on the 3rd line Histori...

Страница 15: ...Type Area Volume Calculations Indirect measurement using Pythagoras Addition Subtraction Continuous Measurement Min Max Distance Tracking Display illumination and multi line display Beep indication Du...

Страница 16: ...2 x 1 5V Auto laser time out after 0 5 min Auto instrument time out after 3 min Dimension 4 4 x 1 9 x 1 1 115 x 48 x 28 mm Weight 5 3 oz 150g LazerTape 160 Users Manual Use target plate to increase m...

Страница 17: ...measurement time too long Distance greater than 160ft Use target plate Reduce distance 209 Received signal too strong Target too reflective use target plate 252 Temperarure too high Cool down instrume...

Страница 18: ...f measurement through liquids or glass is attempted Styrofoam or similar semi permeable surfaces can also cause measurement errors Aiming at high gloss surfaces may reflect the laser and lead to measu...

Страница 19: ...Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Отзывы: