Features 

 

Adjustable carbon monoxide warning level Dual Display

Long life electrochemical sensor Audible alarm

Backlit LCD for easy viewing in dimly lit areas Low battery indicator

Auto power off

Included wrist strap and carry pouch

Safety Information 

 

IMPORTANT SAFETY 

NOTES 

 

The GSM130 Carbon Monoxide Monitor is intended for general 

purpose Air Quality monitoring only, and has not been certified for use 

pursuant to any state or city safety Carbon Monoxide Alarm or 

Monitoring requirements. 

The GSM130 Carbon Monoxide Monitor has not been tested by an 

independent lab to comply with UL 2034 
or IAS 6-96 standard. 

It is the responsibility of the customer to obtain and apply current local, 

state, and national regulations with regard to CO alarms, monitoring 

and testing. 

Electromagnetic (EMI) interference my cause erratic meter readings; 

do not place meter near areas of high 
EMI when taking CO measurements. 

Recovery time is required after the meter has been exposed to high 

levels of CO (the longer the exposure, the longer the recovery time). 

Carbon monoxide is life threatening even at relatively low 
concentrations; learn and recognize the effects of CO 
poisoning (see Table below). Do not use this meter as a 
personal safety monitoring device. 

Содержание GSM130

Страница 1: ...9 parts per million ppm The GSM130 can be used for ambient air safety checks of residential areas appliances HVAC service on furnaces and hot water heaters home inspections and industrial environments where the accumulation of CO is possible 5 Commonwealth Ave 5 Commonwealth Ave Woburn MA 01801 Woburn MA 01801 Phone 781 665 1400 Phone 781 665 1400 Toll Toll Free 1 800 517 8431 Free 1 800 517 8431 ...

Страница 2: ...e Monitor has not been tested by an independent lab to comply with UL 2034 or IAS 6 96 standard It is the responsibility of the customer to obtain and apply current local state and national regulations with regard to CO alarms monitoring and testing Electromagnetic EMI interference my cause erratic meter readings do not place meter near areas of high EMI when taking CO measurements Recovery time i...

Страница 3: ...riod according to OSHA 200 PPM Mild headache fatigue nausea and dizziness after 2 3 hours 400 PPM Frontal headache with 1 2 hours life threatening after 3 hours 800 PPM Dizziness nausea convulsions within 45 minutes Unconsciousness within 2 hours DEATH WITHIN 2 TO 3 HOURS 1600 PPM Headache dizziness nausea within 20 minutes DEATH WITHIN 1 HOUR 3200 PPM Headache dizziness nausea within 5 10 minutes...

Страница 4: ...y Display 4 Unit of measure Button Descriptions Turn the meter on and off short press Select alarm setpoint value long press from a powered OFF state release the button when desired alarm limit is displayed Turn the backlight on and off short press Toggle temperature units long press during self test period Reset Maximum CO value long press in normal operating mode ...

Страница 5: ...er beeps and enters the normal operating mode Measurements The CO15 detects the existence of carbon monoxide CO in the environment and displays the reading in parts per million PPM in the primary display 1 To take a measurement trace the CO15 around the area of the suspected leak 2 The meter indicates the presence of carbon monoxide CO in PPM in the primary display The secondary display indicates ...

Страница 6: ...O levels Change the alarm limit value by following the steps below 1 Turn OFF the meter by pressing the button 2 Long press the button until the options display on the screen 3 The LCD cycles through these options 25 30 35 45 50 70 100 200 ppm 4 Release the button at the desired alarm limit value 5 The meter enters the self test mode Backlight The meter features a backlit LCD for use in dimly lit ...

Страница 7: ... the battery and store separately Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of life devices...

Страница 8: ... 47 x 28mm 6 9 x 1 8 x 1 1 158 8g 5 6 oz Troubleshooting Error Problem Solution Ensure batteries are Display No display when pressing properly installed with power button correct polarity Replace batteries Check for low battery Display Display switches off indicator replace batteries Check for low battery Display Calibration Failure indicator replace batteries E2 Measurement is below Check reading...

Страница 9: ...ply to any of our products which have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as in our sole judgment to injure their stability or reliability or which have been subject to misuse abuse misapplication negligence accident or which have had the serial numbers altered defaced or removed Accessories including batteries are not covered ...