Triplett GSM120 Скачать руководство пользователя страница 2

 

Introduction 

 

 
Congratulations on your purchase of the Triplett GSM120 Carbon Monoxide Meter. The GSM120 
measures and displays CO concentrations between 0 and 1000 parts per million (ppm). 

 

 

Safety Information 

 
 

Carbon monoxide is life threatening even at relatively low concentrations; 
learn and recognize the effects of CO poisoning (see Table below). Do not use 
this meter as a personal safety monitoring device. 

  

 

0-1PPM 

Normal background levels. 

9 PPM 

ASHRAE Standard 62-1989 for living areas. 

50 PPM 

OSHA enclosed space 8-hour average level. * 

100 PPM 

OSHA exposure limit. * 

200 PPM  

Mild headache, fatigue, nausea and dizziness. 

800 PPM 

Dizziness, nausea and convulsions. 
Death within 2 to 3 hours. 

*U.S. Department of Labor, Occupational Safety & Health Administration (OSHA) 
Regulation 1917.24: The CO content in any enclosed space shall be maintained at not 
more than 50 PPM (0.005%). Remove employees from enclosed space if the CO 
concentration exceeds 100 PPM (0.01%). 

 

Ensure that the meter is turned on in an area free of CO. 
If  not,  the  meter  will  read  incorrectly  when 
subsequently measuring CO. 

 
 

Description 

 

 
 
METER DESCRIPTION 

 

1.

 

LCD Display 

 

2.

 

Mode Button, Power/Alarm LED, Select Button 

 

3.

 

Power ON/OFF Button 

 

 

4.

 

CO Sensor 

 

5.

 

Battery Compartment  

 

 

 

            

            

            

             

            

            

            

            

            

           

Содержание GSM120

Страница 1: ...User Manual GSM120 Carbon Monoxide Meter ...

Страница 2: ...space 8 hour average level 100 PPM OSHA exposure limit 200 PPM Mild headache fatigue nausea and dizziness 800 PPM Dizziness nausea and convulsions Death within 2 to 3 hours U S Department of Labor Occupational Safety Health Administration OSHA Regulation 1917 24 The CO content in any enclosed space shall be maintained at not more than 50 PPM 0 005 Remove employees from enclosed space if the CO con...

Страница 3: ...d when the meter is powered off 2 Recall Data Mode Press the SEL button to step through and recall the data from the 10 memory locations The current memory location 0 9 is displayed in the top right REC MAX MEM 3 Store Data Mode In this mode you can store the reading to the next available memory location by pressing the SEL button REC is displayed in the top right 4 Recall Alarm Mode The meter wil...

Страница 4: ... Approx 50 hours with alkaline battery Operating Temperature 0 to 50o C 32 to 122o F Storage Temperature 30 to 60o C 22 to 140o F Operating Humidity 0 to 99 RH non condensing Dimensions 160 x 56 x 40mm 6 3 x 2 2 x 1 57 Weight 180g 6 35oz You as the end user are legally bound EU Battery ordinance to return all used batteries disposal in the household garbage is prohibited You can hand over your use...

Страница 5: ...of purchase This warranty does not apply to any of our products which have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as in our sole judgment to injure their stability or reliability or which have been subject to misuse abuse misapplication negligence accident or which have had the serial numbers altered defaced or removed Accessories...