Maintenance 

 

WARNING:

  To  avoid  electrical  shock,  disconnect  the  meter  from  any  circuit, 

remove  the test  leads from  the input  terminals,  and  turn  OFF  the meter  before 
opening the case. Do not operate the meter with an open case. 
 

 

Cleaning and Storage 

Periodically wipe the case with a damp cloth and mild detergent; do not use 
abrasives or solvents. If the meter is not to be used for 60 days or more, remove 
the battery and store it separately. 

 

Type K Temperature Probe Replacement 

Note:

 

To use a Type K thermocouple probe that is terminated by a 

subminiature (Flat blade) connector, a subminiature-to-banana plug adaptor is 
required. 
 
 
 

Содержание CM1050

Страница 1: ...of the Triplett CM1050 1000A True RMS AC DC Clamp meter The CM1050 True RMS AC DC Clamp meter features AC DC Current measurements up to 1000A Variable Frequency Drive VFD Voltage Measurements Inrush Current Mode Temperature Measurements Non contact AC voltage detection Lo Z Voltage Measurements ...

Страница 2: ... for longer than 60 days CAUTIONS Improper use of this meter can cause damage shock injury or death Read and understand this user manual before operating the meter Always remove the test leads before replacing the battery The meter itself for any damage before operating the meter Repair or replace any damage before use Use great care when making measurements if the voltages are greater than 25VAC ...

Страница 3: ...Description Meter Description ...

Страница 4: ...Display Icons Description ...

Страница 5: ...Operation ...

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ...an open case Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent do not use abrasives or solvents If the meter is not to be used for 60 days or more remove the battery and store it separately Type K Temperature Probe Replacement Note To use a Type K thermocouple probe that is terminated by a subminiature Flat blade connector a subminiature to banana plug adaptor is...

Страница 11: ...Specifications ...

Страница 12: ......

Страница 13: ...General Specifications Dimensions 9 8 x 3 2 1 7 249 81 5 42 2mm Weight 11 5 oz 327g ...

Страница 14: ... date of purchase This warranty does not apply to any of our products which have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as in our sole judgment to injure their stability or reliability or which have been subject to misuse abuse misapplication negligence accident or which have had the serial numbers altered defaced or removed Acces...