AUTO POWER OFF

: After approx. 20 mins, if meter keys are not 

touched, the

 

meter automatically shuts down to preserve battery 

life. 

Specifications 

  

 

General Specifications 

 

Display 

Dual LCD with multifunction 
indicators 

 

Measurements 

Knots, km/h, MPH, ft/min, m/sec, Beaufort force, 
windchill, 

 

and temperature (C/F) 

 

 

Wind-speed 

Moving 2 second average with 2 second gust 
detect 

Sensor 

Sapphire bearing, non-corrosive vane for air 
velocity and 

 

precision thermistor for 
temperature 

 

 

Average Mode 

Choice of 5, 10, or 13 second 
average readings 

 

Max Display 

Push button highest reading 
recall 

 

 

Data hold 

Freeze most recent display 

 

 

Sample time 

1 reading per second 

 

 

Water-resistant 

To 3’ (1 meter) 

 

 

Min/Max wind-
speed 

1.1 to 62.5 MPH 

 

 

Operating 
temperature 

5 to 122

o

F (-15 to 50

o

C) 

 

 

Operating humidity  < 80% RH 

 

 

Power supply 

Lithium battery type CR-2032 or 
equivalent 

 

Battery life 

400 hours approx. 

 

 

Weight 

3 oz. ( 95 g ) 

 

 

Dimensions 

Instrument: 5.25 x 2.75 x 0.75” (133 x 70 x 19mm) 

 

Vane: 1” ( 24mm ) diameter 

 

 

 

 

 

 

 
 

Содержание AM200

Страница 1: ...User Manual AM200 Thermo Anemometer with Wind Speed Wind Chill and Temperature ...

Страница 2: ...onal meter with proper care will provide years of safe reliable service Meter Description 1 Vane impeller 2 Precision thermistor 3 LCD display 4 POWER and HOLD key 5 UNITS and MODE key 6 Battery compartment on rear 7 Swivel handle and storage case 8 Lanyard holder 9 Impeller set screw on rear of meter ...

Страница 3: ... meter Max operation After a measurement session press and hold the UNITS MODE key until the MAX icon appears on the lower left hand side of the LCD Both the Air Velocity and Temperature indication will represent the highest readings measured since the meter was last powered Average mode operation Normally the meter averages readings every 2 seconds To select 5 10 or 13 second averaging first pres...

Страница 4: ...bearing non corrosive vane for air velocity and precision thermistor for temperature Average Mode Choice of 5 10 or 13 second average readings Max Display Push button highest reading recall Data hold Freeze most recent display Sample time 1 reading per second Water resistant To 3 1 meter Min Max wind speed 1 1 to 62 5 MPH Operating temperature 5 to 122o F 15 to 50o C Operating humidity 80 RH Power...

Страница 5: ...battery placing the new one in the same position Secure the battery compartment cover and dispose of the lithium battery in accordance with local state or national disposal codes All EU users are legally bound by the Battery Ordinance to return all used batteries to community collection points or wherever batteries accumulators are sold Disposal in household trash or refuse is prohibited Disposal ...

Страница 6: ...iginal purchaser of these goods for use Triplett warrants to the original purchaser for use that the products sold by it will be free from defects in workmanship and material for a period of 1 one year from the date of purchase This warranty does not apply to any of our products which have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as...

Отзывы: