Operation

Overview:

Your atomizing mister type humidifier operates by dispersing a fine mist into the warm air plenum of your furnace. The 

water is then evaporated and carried into the home by the furnace air flow. This humidifier is recommended for areas 

where water mineral content is low. Otherwise, a fine accumulation of white dust may occur in either the ducts or liv-

ing areas. High mineral content will also clog the nozzle causing an uneven spray pattern, excessive dripping, or total 

blockage of the nozzle tip. When wired properly, the humidifier will operate only when the plenum temperature rises to 

the internal thermostat setting, the humidistat senses a need for humidity, and the furnace blower is in operation. The 

internal thermostat controls the temperature at which the humidifier will turn on. The humidifier should activate after the 

furnace blower comes on and shut off before the furnace blower turns off. If this does not occur, readjust the furnace 

fan switch as required. If applicable, set the humidistat in the recommended range of 35-50% Relative Humidity for 

automatic humidity control during the heating season (a lower setting may be used to control condensation on single 

pane windows). Due to the operation cycle of the furnace and humidifier, it may take two to five days to reach the proper 

humidification level.

Recommeded Relative Hu-

midity Level vs. Outside Air 

Temperature

Outside 

Temperature

Recommended 

Set-point

40°F

45% RH

30°F

40% RH

20°F

35% RH

10°F

30% RH

0°F

25% RH

NOTE:

    When  shutting  the  humdifier  down  for  the  summer  months,  turn  off 

the water and clean any mineral accumulation from the unit.  Leave the water 

turned off.  If the furnace fan is to be used for cooling purposes, disconnect 

power to the humidifier or turn the humidistat to the OFF position if applicable.

Start-up & Operation:

1.  Adjust the humidistat to the ON position and turn the furnace on.

2.  Adjust the house thermostat to cause the furnace to operate. The heat and blower should turn on BEFORE the 

humidifier.

3.  The solenoid valve will make an audible click when it operates, either on or off.

4.  If necessary, adjust the furnace fan control to a lower setting to allow the blower to turn on before the humidifier 

turns on and the blower turns off after the humidifier is off.

5.  Readjust the humidistat to the desired setting (35-50% Relative Humidity is recommended).

6.  If condensation occurs on windows, lower the humidistat setting until the condensation has disappeared.

Содержание Mister-MINI

Страница 1: ...Tr i o n w w w t r i o n i a q c o m READ AND SAVE THESE INSTRUCTIONS Mister MINI Duct Mounted Atomizing Humidifer...

Страница 2: ...ocation Selection 6 Mounting 7 Wiring 8 Plumbing 9 Start up Operation 10 Maintenance To Clean and Inspect 11 To Check for Leaks 11 To Clean Spray Nozzle 12 To Clean Solenoid Valve 13 Unit Diagram and...

Страница 3: ...hold more moisture By using a humidifier a source of water is provided to satisfy this increased moisture holding capability rather than having it drawn from our body surface and the surrounding furn...

Страница 4: ...rriers tight storm windows and doors and a dampered fireplace Air exchange rate of 5 changes per hour An Average Home is insulated and has a dampered fire place but there are no vapor barriers storm d...

Страница 5: ...nozzles at varying water pressures The capacity listed on the nozzle is for 2 fuel oil at 100 psi and should not be considered relative to the water capacity of this humidifier Nozzle Pressure PSI No...

Страница 6: ...control switches air conditioning or heat coils or walls of the duct The humidifier should be mounted so that the furnace air carries the mist away from the humidifier temperature switch The directio...

Страница 7: ...ystems 3 Tape the template included inside the carton in place on the duct 4 Drill the 4 1 8 diameter holes as indicated These are used to secure the unit to the duct 5 Neatly cut out the 3 1 8 x 3 1...

Страница 8: ...difier whenever the circulating air blower is in operation Read the instructions in the furnace installation manual carefully before attempting installation or operation of the humidi fier Failure to...

Страница 9: ...at may get stuck in the solenoid valve seat or clog the spray nozzle When finished turn the saddle valve off again 4 Cut off any excess length of copper water tubing and connect it to the humidifier u...

Страница 10: ...dity for automatic humidity control during the heating season a lower setting may be used to control condensation on single pane windows Due to the operation cycle of the furnace and humidifier it may...

Страница 11: ...aminants can find its way into the air handling system and ultimately the humidifier The humidifier is not the source of these impurities To clean and inspect the unit 1 Turn the power to the furnace...

Страница 12: ...nozzle adapter with a 3 4 wrench and using a 5 8 wrench turn the spray nozzle counter clockwise and remove the nozzle 8 Remove the screen from the nozzle by turning it counter clockwise 9 Holding the...

Страница 13: ...se undue strain on the wiring 7 Remove the solenoid valve assembly from the cover using a Phillips head screwdriver 8 Using a 3 4 wrench remove the brass nozzle adapter from the OUT port of the valve...

Страница 14: ...TAT 1 3 266121 001 G 109C SOLENOID VALVE ASSEMBLY 1 4 266122 001 WIRE ASSEMBLY 2 5 EST 1434 SCREW SST MACH M4 x 6MM 2 6 142983 003 CHRISTMAS TREE CLIP 1 7 AH 25 NPT x COMPRESSION FITTING 1 8 12006 01...

Страница 15: ...l customerservice trioniaq com Humidifiers which have been installed or become part of real estate cannot be returned Trion will receive freight prepaid only removable parts or components of such defe...

Страница 16: ...Trion 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com Trion 2015 All Rights Reserved Form No 265240 001 Rev 02 15...

Отзывы: