    Installation     -   

  

Application 

This air cleaner is used in forced air heating, cooling, and ventilating systems.  The air 
cleaner should be installed in the system such that all the system air is circulated 
through the air cleaner.  Maximum performance is obtained with the system blower set 
for continuous operation. 

 

Installation Requirements 

The best location for the air cleaner is in the return air duct next to the blower 
compartment.  In this location, the blower motor and cooling coils will be kept clean.  
Do not install the air cleaner in the discharge air duct. Do not install the air cleaner 
directly exposed to UV lighting.  Before installing the air cleaner, consider the 
application.  If a transition between the ductwork and air cleaner is required, refer to 
section entitled 

Transitions

, below.  The unit must be readily accessible for periodic 

inspection and replacement of the filter cartridge to maintain maximum efficiency and 
trouble-free operation. A clean coil will reduce utility costs by maintaining the coil’s 
efficiency. Failure to replace filter cartridge can cause damage to the cooling system.  
Allow a minimum of 26” clearance in front of the access panel for filter cartridge 
replacement. 

 

Transitions 

If the air duct does not fit the 
air cleaner cabinet opening, 
gradual transitions are 
recommended to reduce air 
turbulence through the air 
cleaner and maximize 
efficiency.  Not more than 
20° (about 4” per running 
foot) of expansion should be 
used on each side of the 
transition fitting. 

 

 
 
 
 
 

Содержание Air Bear Supreme Series

Страница 1: ...Air Bear Supreme Series Duct Mount Media Air Cleaner Installation Operation Maintenance CAUTION READ INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS CAREFULLY FOR SAFE OPERATION 155595 001 11 09...

Страница 2: ...Table of Contents Table of Contents Page Introduction 1 Unit Components 2 Unit Selection Guide 3 Unit Dimensions 3 Installation 4 Maintenance 8 Notes 9 Warranty Back page...

Страница 3: ...ir passing through it How the Air Cleaner Works Dirty air enters the air cleaner by way of the return air duct system in your home Particles are collected by the special pleated filter media The pleat...

Страница 4: ...SUPREME 20 X 20 MERV 8 UNIT P N 455602 225 255649 003 356066 1709 356066 1017A MERV 11 UNIT P N 455602 725 259112 003 AIR BEAR SUPREME 1400 MERV 8 UNIT P N 455602 125 255649 005 356066 1710 356066 10...

Страница 5: ...OW INCHES W G 600 CFM 0 04 0 05 0 04 0 05 0 06 0 07 0 07 0 09 800 CFM 0 07 0 07 0 08 0 09 0 09 0 12 0 11 0 14 1000 CFM 0 09 0 10 0 12 0 13 0 13 0 17 0 16 0 21 1200 CFM 0 11 0 13 0 15 0 17 0 17 0 23 0...

Страница 6: ...Installation 4...

Страница 7: ...ir cleaner consider the application If a transition between the ductwork and air cleaner is required refer to section entitled Transitions below The unit must be readily accessible for periodic inspec...

Страница 8: ...rn it around and replace in cabinet The directional arrows on the filter cartridge must point in the direction of air flow Humidifiers Location of the system humidifier is important to the operation o...

Страница 9: ...n NOTE The following is a typical installation of the air cleaner on a highboy furnace You may have to alter the installation to fit your specific application 5 Locate the cabinet in the cold air retu...

Страница 10: ...r cartridge into cabinet with AIR FLOW arrow pointing in the direction of airflow 5 Replace door and place used filter in plastic bag for easy disposal Replacement Filter Cartridges for your Media Air...

Страница 11: ...____________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________...

Страница 12: ...eceived an adequate response from the dealer or distributor notify in writing by phone or email Trion 101 McNeill Road Sanford NC 27330 1 800 884 0002 customerservice trioninc com 6 This limited warra...

Отзывы: