Страница 1: ...447 C1 Duct Mount Humidifier Manual for Installation Operation Maintenance Caution Read installation and rules carefully for safe operation Exercise the usual precautions when working with electricity...
Страница 2: ...Table of Contents Page Introduction 1 Specifications 4 Operation of Humidifier 5 Maintenance 6 Installation Physical Installation 8 Electrical Installation 11 Unit Diagram and Parts List 13...
Страница 3: ...5 50 are enjoyed by everyone living in such an comfortable environment These benefits include both personal comfort and the preservation of furniture draperies carpets wooden floors and cabinets paint...
Страница 4: ...quently As stated a properly main tained and efficiently operating humidifier is a source of improved IndoorAir Quality and personal comfort The necessity to clean your humidifier is substantially the...
Страница 5: ...lm or scale to build up on the unit evaporator pad or any moving part and reduce the efficiency of the humidifier An algaecide such as a humidifier cleaning tablet or bacteriostatic liquid powder can...
Страница 6: ...5 16 11 X9 Duct Opening W x H 8 3 4 X2 7 8 Shipping Weight 6lbs Standard Equipment Wall duct mounted humidistat Self piercing saddle valve 6 flange damper Features Externally held evaporative media I...
Страница 7: ...for use with either hard or softened water Set the humidistat in the recommended range of 30 50 relative humidity for automatic humidity control during the heating season a lower setting may be used...
Страница 8: ...1 Turn the power to the furnace OFF 2 Set the humidistat to the OFF position and disconnect the humidifier from the power source 3 Turn off the water at the saddle valve by turning clockwise 4 Remove...
Страница 9: ...n to the duct by tilting it to engage the back edge of the opening under the tangs Lower the front edge to the level position and engage the 2 pins located on the sloped bottom into the matching holes...
Страница 10: ...arefully to ensure safe operation Failure to follow them could damage the product or cause a hazardous condition 2 Check the ratings given on the product to make sure it is suitable for your applicati...
Страница 11: ...e could occur from accidental overflow connect a 1 211 drain hose to the brass overflow 18 Do NOT solder the line directly to the humidifier because heat can warp and damage the pan 19 Turn the humidi...
Страница 12: ...duct wires behind 3 lugs located on the inside of the unit bypass opening 26 2 hose clamps are required and the bypass duct should be level for best results NOTE Installation kit contains 251 of 5 fle...
Страница 13: ...s may result in improper installation and therefore void the manufacturer s warranty 1 Turn the humidistat to the highest level past 60 and the humidifier should begin to run The humidifier should sto...
Страница 14: ...umed to be well insulated with vapor barriers tight storm doors and windows and a dampered fireplace Air change rate of 50 changes per hour An Average House is insulated and has a dampered fireplace b...
Страница 15: ...1 11 16 I r 3 i 12 7 13 4 18 I t 17 10 2 1410 3 1223 4 1307 5 1306 6 1413 7 1425 8 1402 9 1247 10 24088 11 1412 12 1405A 13 1322 14 1415 15 1407 16 1403 17 1400 18 1409 19 1020 20 1408A 22 1406 N A No...
Страница 16: ...moders of the electronic air cleaner or humidifier may be returned intact freight prepaid but electronic air cleaners or humidifiers which have been installed or become part of real estate cannot be...