MODEL TES18 & TES25 

UV SYSTEMS

FOR RESIDENTIAL SPAS & SWIMMING POOLS

INSTALLATION & OPERATING

INSTRUCTIONS 

TEL NO: (44) (0) 141 810 4861  FAX NO: (44) (0) 141810 5561  E-MAIL:  [email protected]

TRIOGEN LTD.  TRIOGEN HOUSE,  CRAIGTON, GLASGOW. G52 1BD.SCOTLAND 

Содержание TES18

Страница 1: ...UV SYSTEMS FOR RESIDENTIAL SPAS SWIMMING POOLS INSTALLATION OPERATING INSTRUCTIONS TEL NO 44 0 141 810 4861 FAX NO 44 0 141810 5561 E MAIL info triogen com TRIOGEN LTD TRIOGEN HOUSE CRAIGTON GLASGOW...

Страница 2: ...e fluctuations in bather loading temperature changes sunshine which dissipates chlorine etc are not taken into consideration So how does one ensure the health of those using the pool without having sp...

Страница 3: ...ials When you add chlorine to a pool extreme care must be taken not to overdose the pool water and cause harm to the bathers UV has the advantage over Chlorine in that UV does not add any chemical to...

Страница 4: ...on SIZING SELECTION OF THE EQUIPMENT The correct selection of the unit is imperative if the water is to be correctly treated with a UV dose of 30mj cm2 which is the required does rate for effective di...

Страница 5: ...has to be fitted in the pool filtration pipework system and should be located after filtration as shown in the diagram below It is recommended that isolating valves are fitted within the inlet and out...

Страница 6: ...gaskets onto the face of the union tailpieces and then secure in position by threading the half union nut on the TES unit onto the tailpiece NOTE DO NOT OVERTIGHTEN THE UNION NUT HAND TIGHTENING SHOU...

Страница 7: ...SSING OF THE CONNECTIONS 8 The PVC pipework used for the installation should be glued into the union tailpieces using suitable PVC primer and cement as recommended by the pipework supplier 9 The conne...

Страница 8: ...TES UV 25 80W 0 58A The plug or fused spur should be fitted with a 3A fuse The circuit for the socket fused spur must be protected by an earth leakage device such as an RCD or ELCB unless a plug is us...

Страница 9: ...the maximum pressure rating of 40 psi is not being exceeded 6 Check that the mains power supply to the unit is switched off and then remove the top cap of the unit to allow inspection of the UV react...

Страница 10: ...till exists release the top union nut which will allow a little water to escape and the pressure should drop to ZERO Remember to re tighten the nut 6 Remove the top electrical cover Depending on the t...

Страница 11: ...ECREASE THE UV TRANSMISSION CHARACTERISTICS OF THE HIGH QUALITY QUARTZ FROM WHICH THE THIMBLE IS MANUFACTURED 16 After cleaning the outer surface ensure that the thimble is completely dry both externa...

Страница 12: ...e care not to touch the glass surface with bear hands 25 Slide the lamp into the glass thimble taking care that the top two o rings remain on the lamp ceramic end and go into the glass thimble These o...

Страница 13: ...lamp plug and lamp end socket are visible 7 Hold the lamp only by the lamp end piece not the glass and remove the lamp connection plug 8 It is now possible to fully remove the UV lamp 9 Fit the lamp...

Страница 14: ...8 TES25 TES18 TES25 TES18 TES25 TES18 25 TES18 25 TES18 25 TES18 25 TES18 25 TES18 25 TES18 25 TES18 25 TES18 25 UV LAMP UV LAMP UV LAMP THIMBLE UV LAMP THIMBLE UV LAMP BALLAST UV LAMP BALLAST THIMBLE...