UNIPLAY
10
270.97mm
212.97mm
201mm
259mm
50mm
R2mm
CUTOUT DIMENSIONS
A
C
B
D
E
G
F
H
I
K
J
Страница 1: ... Please refer to the Motion Coordinator Technical Reference Manual for Full Details HMI UNIPLAY Quick Connection Guide H H IPLAY HM HM PLAY MI MI ...
Страница 2: ...it in areas subject to explosion hazards due to flammable gases vapours or dusts The unit should not be installed where large temperature variations and or high humidity is present This will cause condensation in the device Do not install UNIPLAY in environments where have inflammable gases MOUNTING Care should be taken when locating equipment behind the unit to ensure that a c power wiring PLC ou...
Страница 3: ...unit Contact your local authorities to determine which codes apply Power Requirements The UNIPLAY is powered by d c power only The specified voltage range is 24 20 Volts d c This insures compatibility with most controller d c systems The power conditioning circuitry inside the unit is accomplished by a switching power supply The peak starting current can be as high as 2A Fusing Requirements If the...
Страница 4: ...r screw counterclockwise until the gap is wide open insert the wire all the way in and turn the screw clockwise until tight Connect positive d c line to the 24V terminal and the d c ground to the 0V terminal Grounding Requirements A CHASSIS GROUND MUST BE USED The d c ground is not directly coupled to Earth ground internally It is not advisable to ground the d c negative return to chassis ground a...
Страница 5: ...ed to connect the UNIPLAY screen to a Motion Coordinator or Ethernet switch Speaker An external speaker buzzer may be used for greater keypress feedback Connection is via a 3 5mm mono jack plug DIP switch settings SW1 SW2 SW3 SW4 Mode ON OFF OFF ON Touch Screen Calibrate mode OFF ON OFF ON Hide HMI System Setting Bar OFF OFF ON ON Boot Loader mode OFF OFF OFF ON Normal OFF OFF OFF OFF Not Supporte...
Страница 6: ... operator HMI screens which are transferred to the UNIPLAY HMI by the Motion Coordinator at runtime Trio recommend using a USB powered switch CONFIGURATION RUNNING Default controller address 192 168 0 250 Default HMI IP address 192 168 0 251 To change the controller IP address the HMI requires use Motion Perfect v3 ...
Страница 7: ......
Страница 8: ...om3 RS485 Com3 RS232 B Fuse H Com1 RS232 Com2 RS232 C Power connector I Ethernet port D VESA 75mm screw holes J USB Host port E Line out K USB Client port F SD card slot UNIPLAY 7 200 35mm 146 35mm 138mm 192mm 42 55mm R2mm CUTOUT DIMENSIONS A C B D E G F H I K J ...
Страница 9: ...UNIPLAY 10 270 97mm 212 97mm 201mm 259mm 50mm R2mm CUTOUT DIMENSIONS A C B D E G F H I K J ...
Страница 10: ...quick start v1 July 2012 Trio Motion Technology Ltd Trio Motion Technology LLC Trio Shanghai Trio India WWW TRIOMOTION COM ...