![Trio MC4N-ECAT Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/trio/mc4n-ecat/mc4n-ecat_quick-start-manual_1163419011.webp)
11
CHASSIS MOUNTING DIMENSIONS (LOOKING FROM FRONT)
M4 screws should be used in 2 places to mount the MC4N to an unpainted metal
panel.
The best EMC performance is obtained when the MC4N is attached from the shield
screw (marked) using a flat braided conductor with a cross section of 4mm x 1mm.
Do NOT use a circular section wire or run the braid to a central star point.
0
0
ENSURE THAT THE VENTILATION SLOTS AT THE TOP AND BOTTOM OF THE
MC4N ARE KEPT CLEAR TO ENSURE A FREE FLOW OF AIR THROUGH THE
MODULE.
38.6
19.3
19.3
4
145.8
4
4.5
4.5
Shield Screw