© Copyright 2007 Trio DataCom Pty. Ltd. 

O Series Data Radio – User Manual

Other Related Documentation 

and Products

Revision History

Issue 1 

May 2007 

Initial Release

Issue 2       Jun 2007 

Minor FCC Modifications

Part B – O Series Overview

WEEE Notice (Europe)

This symbol on the product or its packaging indicates that this 

product must not be disposed of with other waste. Instead, it is 

your responsibility to dispose of your waste equipment by handing 

it over to a designated collection point for the recycling of waste 

electrical and electronic equipment. The separate collection and 

recycling of your waste equipment at the time of disposal will help 

conserve natural resources and ensure that it is recycled in a 

manner that protects human health and the environment. For more 

information about where you can drop off your waste equipment 

for recycling, please contact the dealer from whom you originally 

purchased the product.
Dieses Symbol auf dem Produkt oder seinem Verpacken 

zeigt an, daß dieses Produkt nicht mit anderer Vergeudung 

entledigt werden darf. Stattdessen ist es Ihre Verantwortlichkeit, 

sich Ihre überschüssige Ausrüstung zu entledigen, indem es 

rüber sie zu einem gekennzeichneten Ansammlungspunkt 

für die Abfallverwertung elektrische und elektronische 

Ausrüstung übergibt. Die unterschiedliche Ansammlung und 

die Wiederverwertung Ihrer überschüssigen Ausrüstung zu der 

Zeit der Beseitigung helfen, Naturresourcen zu konservieren 

und sicherzugehen, daß es in gewissem Sinne aufbereitet wird, 

daß menschliche Gesundheit und das Klima schützt. Zu mehr 

Information ungefähr, wo Sie weg von Ihrer überschüssigen 

Ausrüstung für die Wiederverwertung fallen können, treten Sie 

bitte mit dem Händler in Verbindung, von dem Sie ursprünglich das 

Produkt kauften.

Important Notices for Class I, Division 2, 

Groups A, B, C & D Hazardous Locations 

Applies to models OM900-xxxxx-x

H

x(CSA Marked)

This product is available for use in Class I, Division 2, Groups 

A, B, C & D Hazardous Locations. Such locations are defined in 

Article 500 of the US National Fire Protection Association (NFPA) 

publication NFPA 70, otherwise known as the National Electrical 

Code and in Section 18 of the Canadian Standards Association 

C22.1 (Canadian Electrical Code).
The transceiver has been recognised for use in these hazardous 

locations by the Canadian Standards Association (CSA) 

International. CSA certification is in accordance with CSA Standard 

C22.2 No. 213-M1987 and UL Standard 1604 subject to the 

following conditions of approval:
1. The radio modem must be mounted in a suitable enclosure so 

that a tool is required to gain access for disconnection of antenna, 

power and communication cables.
2. The antenna, DC power and interface cables must be routed 

through conduit in accordance with the National Electrical Codes.
3. Installation, operation and maintenance of the radio modem 

should be in accordance with the radio modem’s user manual and 

the National Electrical Codes.
4.  Tampering or replacement with non-factory components may 

adversely affect the safe use of the radio modem in hazardous 

locations and may void the approval.
5. A power connector locking screws as supplied by Trio Datacom 

MUST

 be used.

 WARNING EXPLOSION HAZARD

Содержание OM900

Страница 1: ...Page 1 Copyright 2007 Trio DataCom Pty Ltd O Series Data Radio User Manual User Manual OM900 Data Radio www triodatacom com...

Страница 2: ...o 5 O Series Product Range 5 O Series Features and Bene ts 5 Standard Accessories 6 Part C Applications 7 Application Detail 7 Part D Module Pinouts 8 Part E System Planning and Design 10 Understandin...

Страница 3: ...supplied may be divulged to any third party without the express written permission of Trio DataCom Pty Ltd Same are proprietary to Trio DataCom Pty Ltd and are supplied for the purposes referred to i...

Страница 4: ...wird da menschliche Gesundheit und das Klima sch tzt Zu mehr Information ungef hr wo Sie weg von Ihrer bersch ssigen Ausr stung f r die Wiederverwertung fallen k nnen treten Sie bitte mit dem H ndler...

Страница 5: ...ense free frequency band and the OM240 that can be con gured for use in the 2 4GHz license free bands available throughout the world O Series Features and Bene ts Radio License free communication in i...

Страница 6: ...Antenna Grid Re ector 24dBd Gain 2 4GHz ANT2G4WHIP Antenna Omni Dirn Whip TNC Demo Use 2 4GHz ANT2G4OMNI Antenna Omni Dirn Unity Gain 2 4GHz ANT2G4 6OM Antenna Omni Dirn 6dBd Gain 2 4GHz Note 1 Freque...

Страница 7: ...multipoint multiple access applications for remote interconnection of PLCs RTUs dataloggers and other data monitoring and control devices including specialist utility devices such as powerline ACRs In...

Страница 8: ...d every 1500ms for 100ms when master acquired additional 100ms pulse when user data received Active Low 3 3V TTL 18 TxD_PORT1_LED O Pulsed for 100ms for any TxD activity for Port 1 Port B on K Series...

Страница 9: ...Flow control of RxD for Primary Data Port Port B on K Series 3 3V TTL 34 PORT1 DCD O Flow control of RxD for Port 1 Port B on K Series 3 3V TTL 35 TWD IO I2C Data IO 3 3V TTL 36 TWCK O I2C Clock 3 3V...

Страница 10: ...ctions hills buildings foliage horizon effectively the bulge between two points on the earth and factors such as fog heavy rain bursts dust storms etc In order to ascertain the available RF coverage f...

Страница 11: ...tively decreased signal in the unwanted direction i e interference rejection properties Selecting Antennas Antennas There are basically two types of antennas omni directional and directional Omnidirec...

Страница 12: ...stablilise the antenna under windy conditions Alignment of Directional Antennas This is generally performed by altering the alignment of the antenna whilst measuring the received signal strength If t...

Страница 13: ...C regulated supply The power supply must be able to supply suf cient current to provide clean ltered DC under the full current conditions of the radio modem i e when transmitting full RF power Site Ea...

Страница 14: ...abling For FCC compliance the O Series module antenna connection MMCX may only be extended with a patch cable using a reverse TNC bulkhead connector Product Labelling When this OEM module is housed in...

Страница 15: ...n Remotes Bridges Pulsed every 1500ms for 100ms when master acquired additional 100ms pulse when user data received Green Pulsed every 1500ms for 100ms when master not acquired Red Port AActivity Puls...

Страница 16: ...ge 2 5ppm Supply Rails DC Supply 1 5 0V 5 DC Supply 2 3 3V 5 Current Consumption 10dBm output power 130mA 25 C 5 0V 20dBm output power 240mA 25 C 5 0V 30dBm output power 820mA 25 C 5 0V RX 0mA 5 0V 19...

Страница 17: ...ies BMO902H 7dBd 900 MHz Omni Directional Antenna Bluewave Marathon Series BMO902G 6dBd 900 MHz Omni Directional Antenna Bluewave Marathon Series BGO902G 6dBd 900MHz Omni Directional Antenna Bluewave...

Страница 18: ...ut notice Copyright 2007 Trio DataCom Pty Ltd All rights reserved Issue 06 07 HEAD OFFICE 41 Aster Avenue Carrum Downs Victoria Australia 3201 Phone 613 9775 0505 Fax 613 9775 0606 sales triodatacom c...

Отзывы: