background image

7

6

AMPLITUDE

16

 

USER MANUAL

SPECIFICATIONS

ABOUT THE AMPLITUDE

16

SPECIFICATIONS

PRESENTATION

Like all Trinnov power amplifiers, the Amplitude

16

 is designed to match the Altitude AV Processor range. 

This match is achieved both in aesthetics and performance. The input level sensitivity of the Amplitude

16

 

matches perfectly the Altitude output level to maximize dynamic range and signal-to-noise ratio. To 
extract maximum performance, a custom dual power supply and a bespoke thermal dissipation design 
have been developed.

Feature rich, the Amplitude

16

 also provides unprecedented versatility. With the ability to bridge any pair of 

channels, the Amplitude

16

 meets the various requirements of immersive sound home theaters.

IMPORTANT RECOMMENDATION

Before turning on your Amplitude

16

, make sure you are using the right fuses: 2x 10A 5x20mm slow blow. 

Use both Power Inlets.

AUDIO POWER

ONE CHANNEL 8Ω

200W - 1kHz, 0,1%< THD+N

ONE CHANNEL 4Ω

400W - 1kHz, 0,1%< THD+N

ONE CHANNEL BRIDGED 8Ω

800W - 1kHz, 0,1%< THD+N

ONE CHANNEL BRIDGED 4Ω

1000W - 1kHz, 0,1%< THD+N

TOTAL OUTPUT POWER

(SE or BTL)

2800W all channels driven @40°C continuous, 120 VAC

3200W all channels driven @40°C continuous, 230 VAC

GAIN

16 dB single ended / 22 dB bridged

AUDIO PERFORMANCE

THD+N SINGLE ENDED

0.0015% - 8Ω, 5W (2dBu)

THD+N BRIDGED

0.0015% - 8Ω, 20W (8dBu)

FREQUENCY RESPONSE

+0/-0,6 dB 20 Hz to 20 kHz, load-independent

DAMPING FACTOR

2340 at 100Hz / 1820 at 1kHz / 354 at 10kHz

SIGNAL TO NOISE RATIO

126 dB referenced to rated 1% THD output (A-Weighted)

CROSSTALK

96 dB single ended 200W 8Ω

POWER SUPPLY

POWER REQUIREMENTS

2x 100/240V (auto-selecting)

POWER CONSUMPTION

0,5W< at Standby; 125W at idle; Max 2x 2000W fully loaded

THERMAL CONVERSION

683 BTU/h MAX

MAINS FUSE

2x 10 Amp slow blow for different Voltages & Countries

TRIGGER INPUT

5-15 VDC; Steady State (mini-jack TS)

TRIGGER OUTPUT

8-10 VDC; Steady State (mini-jack TS)

MODES /PROCESS

Standby: Amplifier is ready to be turned on via front panel switch or

remote trigger.

Overcurrent, D.C., and/or thermal protection: Amplifier will cycle.

Catastrophic D.C. or output stage failure: Amplifier will shut down.

AUDIO INPUTS & OUTPUTS

INPUT CONNECTOR

2x DB25 Female, Tascam Analog Pinout

INPUT IMPEDANCE

47kΩ, each phase

INPUT SENSITIVITY

6.16V (+18dBu) RMS balanced in = 200W into 8Ω single ended out

OUTPUT CONNECTOR

1x 5 way binding post per channel

Содержание Amplitude 16

Страница 1: ...www trinnov com USER MANUAL ...

Страница 2: ...h the Amplitude16 Trinnov Audio delivers the highest possible performance in a very cost effective package with unprecedented versatility Version 1 0 Last update June 2021 f Contents IMPORTANT SAFETY INSTRUCTIONS 4 ABOUT THE AMPLITUDE16 6 PRESENTATION 6 IMPORTANT RECOMMENDATION 6 SPECIFICATIONS 7 THE FRONT PANEL 9 THE REAR PANEL 10 ENVIRONMENTAL NOTICE 11 OPERATION 11 CHANNEL BRIDGING 12 REMOTE TR...

Страница 3: ...d by the manufacturer Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider that the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Bef...

Страница 4: ...SE or BTL 2800W all channels driven 40 C continuous 120 VAC 3200W all channels driven 40 C continuous 230 VAC GAIN 16 dB single ended 22 dB bridged AUDIO PERFORMANCE THD N SINGLE ENDED 0 0015 8Ω 5W 2dBu THD N BRIDGED 0 0015 8Ω 20W 8dBu FREQUENCY RESPONSE 0 0 6 dB 20 Hz to 20 kHz load independent DAMPING FACTOR 2340 at 100Hz 1820 at 1kHz 354 at 10kHz SIGNAL TO NOISE RATIO 126 dB referenced to rated...

Страница 5: ...l power button to exit the standby mode and start the amplifier 3 POWER LED The Power LED indicates when The Amplitude16 is on standby dimmed red The Amplitude16 is booting waving green The Amplitude16 is powered on full white They are indicating Normal operation white clipping red protection blinking red Bridge Status for each pair of channels vertical LED bar With the optional AoIP input board o...

Страница 6: ...tude16 caused by improper operation wiring and or ventilation will not be covered under warranty and Trinnov Audio will not be liable for any consequential damage or loss When the amplifier is connected it goes into Standby The amplifier is completely off save for a minimal and low power supply to power the soft start circuit When the Standby button is pressed the soft start sequence begins and th...

Страница 7: ...steady state signal received on the trigger input to switch downstream devices on and off Common Practices Avoid specifying the Amplitude16 to drive very low impedance drivers Avoid bridging adjacent channels Split bridged channels across the two circuits Example Power supply 1 outputs 1 2 bridged Power supply 2 outputs 9 10 bridged NOTE Make sure to use a mono TS 35mm mini jack cable for 12V trig...

Страница 8: ...low each DB25 connector Consequently if you are using a 8x XLR to DB25 breakout to connect your preamplifier to the Amplitude16 you will lose one XLR on your cable for every pair of bridged channels As an exemple in case you bridge channels 1 2 and 9 10 you will not use the XLR 2 and 10 from your DB25 XLR Breakout to the processor H Hot C Cold G Ground RACK EARS The total width of the amplifier in...

Страница 9: ...Trinnov Audio 5 rue Edmond Michelet 93360 Neuilly Plaisance France 33 0 1 84 23 40 34 highend trinnov com ...