Triner Scale TS60-1010 Скачать руководство пользователя страница 8

Assembly Guide 

 

 

 

         TS60-1010 Platform Scale 

 

11) Attach the Ramps to the Weighing Base 

SYNOPSIS:  
The ramps are placed into position at the end of the weighing deck, then the weighing 
deck is lowered to the floor, one corner at a time. The two load cell feet at the end of the 
weighing deck fit into holes in the ramp tabs, as shown in Fig. 9. 

 
a) ALIGN THE FIRST RAMP: Using a forklift, position the ramp near the weighing 
deck so that the large tabs are aligned with the feet located at the end of the weighing 
deck, as shown in Fig. 10. 
 
b) LOWER ONE CORNER OF THE WEIGHING DECK INTO THE LOAD CELL 
FOOT HOLE: Using a 5 lb rubber mallet, strike the handle of the ramp to move the ramp 
into position directly under the load cell foot (alternatively, a long pry bar may be used to 
move the ramp into final position). Using a forklift, lift the end of the weighing deck 
enough to remove the end block(s), then slowly lower the deck into position, making sure 
the load cell foot fits into the foot hole in the ramp tab. 
 
NOTE: If required, rearrange the blocks in a way so as each corner of the weighing deck 
can be individually lowered into the ramp tab foot holes. 
 
c) LOWER THE OTHER CORNER OF THE WEIGHING DECK INTO THE 
REMAINING LOAD CELL FOOT HOLE OF THE SAME RAMP: Follow the 
instructions in Step b above to complete the attachment of the ramp to the weighing deck. 
 
d) FOLLOW STEPS A THROUGH C ABOVE TO ATTACH THE SECOND RAMP 
TO THE WEIGHING DECK. After both ramps are attached, the weighing deck will be 
fully lowered to the floor. 

 
12) Adjust the Load Cell Feet to Assure the Weighing Deck is Level and Stable 

a) ADJUST THE FOUR CORNER FEET: Using a 27 mm wrench, adjust the corner feet 
as needed to obtain a level weighing deck. Be sure the weighing deck does not rock or tilt 
from corner to corner. 
 
b) ADJUST THE TWO MIDDLE FEET: Using a 27 mm wrench, adjust the two middle 
feet downward until a solid contact is made with the floor.  

 

13) Connect the Digital Indicator and Check Scale Operation  

a) MOUNT THE INDICATOR BRACKET TO THE INDICATOR STAND: Using the 
provided bolts, bolt the indicator bracket to the indicator stand. Place the stand in the 
desired location of use.  
 
b) CONNECT THE DIGITAL INDICATOR TO THE WEIGHING DECK: Connect the 
digital indicator cable lead from the junction box to the short cable lead from the digital 
indicator. Plug the digital indicator in to 110VAC. Check operation of the scale and 
digital indicator. 
 

Содержание TS60-1010

Страница 1: ...ASSEMBLY GUIDE TS60 1010 Platform Scale Series 2 V 2 0...

Страница 2: ...Securely Bolt Down the Entire Weighing Deck Side Rails Assembly 4 7 Attach and Securely Fasten the Two Guard Rails 5 8 Connect All Load Cell Cables Into the Junction Box Terminals 5 9 Connect the Dig...

Страница 3: ...lift is required during scale assembly It is the user s responsibility to observe and practice forklift safety rules Electrical Safety Wiring connections are required during assembly It is the user s...

Страница 4: ...y Forklift Impact Wrench 19mm Socket Wrench 30mm Socket Wrench 5 lb Rubber Mallet Long pry bar 5 16 Allen wrench Standard Size Flat Head Screw Driver Small Flat Head Screw Driver Hammer Drill bit bit...

Страница 5: ...osition where each side rail will be placed Forklift the side rails into position resting it on top of the blocks Position the side rails parallel to each other Space the rails 10 4 apart allowing roo...

Страница 6: ...the Left Side Rail Cable Exit Hole Unbundle the three load cell cables in the rail Route the cables under the rail s top plates and out the cable exit hole then across the rear beam of the first weigh...

Страница 7: ...s to the terminal block Securely tighten the strain relief collar to lock the cable into position b Feed Load Cell Cables 2 6 Into the Junction Box and Connect All Wires to the Terminal Blocks Followi...

Страница 8: ...y lowered into the ramp tab foot holes c LOWER THE OTHER CORNER OF THE WEIGHING DECK INTO THE REMAINING LOAD CELL FOOT HOLE OF THE SAME RAMP Follow the instructions in Step b above to complete the att...

Страница 9: ...Deck Top Access Panels Securely bolt down the access panels lightly tightening the four corner bolts on the panel then working from side to side tightening the other bolts Secrely tighten all bolts 16...

Страница 10: ...Assembly Guide TS60 1010 Platform Scale Appendix i Figure 1a COMPLETE ASSEMBLY...

Страница 11: ...Assembly Guide TS60 1010 Platform Scale Appendix ii Figure 1b WEIGHING DECK ASSEMBLY...

Страница 12: ...Assembly Guide TS60 1010 Platform Scale Appendix iii Figure 1c RAMP MOUNTING TABS AND HANDLING PRECAUTIONS...

Страница 13: ...Assembly Guide TS60 1010 Platform Scale Appendix iv Figure 2 PLACE SIDE RAILS ONTO WOOD BLOCKS Figure 3 PLACE THE FIRST DECK INTO POSITION AND LOOSELY BOLT TO SIDE RAILS...

Страница 14: ...Assembly Guide TS60 1010 Platform Scale Appendix v Figure 4 ONLY USE SHORT BOLTS NEXT TO LOAD CELLS Figure 5 ROUTING THE LOAD CELL CABLES...

Страница 15: ...Assembly Guide TS60 1010 Platform Scale Appendix vi Figure 6 PLACE THE SECOND DECK INTO POSITION AND LOOSELY BOLT TO SIDE RAILS...

Страница 16: ...Assembly Guide TS60 1010 Platform Scale Appendix vii Figure 7 JUNCTION BOX Wiring Diagram...

Страница 17: ...Assembly Guide TS60 1010 Platform Scale Appendix viii Figure 8 JUNCTION BOX Attached at Side Rail 1 Figure 9 ALIGN RAMP TAB TO WEIGHING DECK LOAD CELL FOOT...

Страница 18: ...Assembly Guide TS60 1010 Platform Scale Appendix ix Figure 10 MOVE RAMP INTO POSITION UNDER WEIGHING DECK LOAD CELL FOOT Figure 11 FULLY ASSEMBLED SCALE...

Страница 19: ...or logo or the serial number be removed or the product fail to be properly maintained or fail to function properly as a result of misuse abuse improper installation neglect improper shipping damage c...

Страница 20: ......

Отзывы: