Page 2-3
is approximately
½
” above the opening and so that the scale is in a level position.
Tighten the locknuts on the leveling feet.
7. Use the Scale Anchor Holes at each corner (
see fig. 2-2
) to secure the scale base in
place with the eight (8) wood screws provided.
8.
The scale base must be grounded
with the lead attached to the top frame. The center
screw on an electrical outlet or a metal conduit is usually suitable. Leave some slack in
the wire. Do not pull the wire tight because it can negatively affect weighing
performance.
2.3 Scale Base Installation (600-E Full Well Style)
1. Remove the stainless steel platform cover by lifting it straight up. Remove the carton of
electronics and hardware wedged between the scale structures. Open the carton and
verify that all components are present (
see table 2-1
).
2. Tilt the scale base on one of its edges to access the bottom of the scale. Remove the
¼
”
shipping screw from the bottom of the scale (
see fig. 2-4
). If this screw is not removed
the scale
will not operate correctly
.
Fig. 2-4: Bottom of Scale (Shipping Screw)
3. Remove the locknuts from the four (4) Leveling Feet. Thread the leveling feet all the way
into the nuts welded in all four (4) corners of the scale lower frame (
see fig. 2-5
). Once
the leveling feet are installed thread the locknuts back onto the top side of the leveling
feet (hand tight).
Fig. 2-5:
Corner Detail
4. Before beginning installation into the counter it is recommended to perform an initial
check of the scale system. Set the scale base on the floor, level the scale and plug all
components into the control module. All the ports on the control module and cables are
clearly marked (
see
fig. 2-3
for System Block Diagram
). Place stainless steel platter