COULD CAUSE A PUMP, WHICH HAS LOST PRIME, TO CONTINUE TO OPERATE
WITHOUT REACHING PRIME. THIS COULD CAUSE DANGEROUS OVERHEATING OF
THE PUMP AND POSSIBLY RUPTURE THE PUMP CASING.
BEFORE SERVICING, ALLOW SUFFICIENT TIME FOR THE OVERHEATED PUMP TO
COMPLETELY COOL. ONCE THE PUMP HAS COMPLETELY COOLED, DRAIN THE
LIQUID FROM THE PUMP BY REMOVING THE CASING DRAIN PLUG. WHEN
REMOVING THE DRAIN PLUG, USE CAUTION. FAILURE TO DO SO MAY RESULT IN
INJURY. PLATES, COVERS, GAUGES, OR FITTINGS MUST NOT BE REMOVED FROM
AN OVERHEATED PUMP. LIQUIDS IN THE PUMP CAN REACH BOILING
TEMPERATURES AND PRESSURE INSIDE THE PUMP CAN CAUSE PARTS TO BE
EXPELLED VIOLENTLY.
G. WSP™ AUTOMATIC AIR RELEASE VALVE (WSP™ ARV)
The WSP™ ARV allows air release through the bypass line.
If
the WSP™ ARV is
installed and set correctly to the appropriate hydraulic operating specifications for
your application, the WSP™ ARV then closes automatically when the pump is
completely primed and operating at full capacity.
Part Number
ARV Minimum Required Pressure
0730059-3
6 psi
0730059-4
10 psi
0730059-5
24 psi
NOTE:
ARV pressure is based on the gauge pressure seen at discharge of pump.
1. Theory of Operation
See Figures 14 and 15 for a cross-sectional view of the WSP™ ARV
and a description of its operation.
Figure 14: Valve in Open Position
Содержание 8-WSP
Страница 62: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 62 ...
Страница 63: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 63 ...
Страница 64: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 64 ...
Страница 65: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 65 ...
Страница 66: ...WSP DATA SHEET WSP SELF PRIMER PUMPS WSP D300_8 Rev 3 01 09 20 2019 The Factory 66 ...