Trigon Monolog Скачать руководство пользователя страница 13

 

 

[ 12 ] 

BAL/UNBAL input selector

 

  
Selects  the  appropriate  input  BAL  on  XLR/UNBAL  on  Cinch  (RCA).  The  selected 
input is displayed by the

  BAL/UNBAL

 

LED

 

Display

 (

7

). 

 
 

[ 13 ]

  “AUTO“ Switch

 

 
Activates  the  automatic  power  mode.  With

  TRIGGER

  mode  selected,  the 

Monolog

 amplifier will turn on as soon as a sufficiently strong (loud) audio signal 

is detected at the input terminals. 
In

  10V  DC

  mode

 

the 

Monolog

  amplifier  will  turn  on  when

 

DC  (approx.  +4V  to 

+10V)

 

is present at the 

REMOTE 10V DC

 (

21

) terminal on the rear panel. Such DC 

trigger outputs are featured on some preamplifiers. This option offers the advantage 
that power amplifiers will be turned on or off whenever the preamplifier is switched on 
or  off. The  selected automatic power  mode is  indicated  by  the 

TRIGGER  / 10V  DC 

LED Display 

(

8

 
Note:  If  one  of  the 

AUTO

  power  options  is  selected,  the  main  power  switch  on  the 

Monolog

 

amplifier has to remain in the ON position.  

Hint:

  We  recommends  to  preferably  using  the 

10V  DC  Mode

  (if  available).  This 

makes sure that not even the quietest opening passages are being missed.  
 
 

[ 14 ]

  UNBAL Input

 

  
To connect unbalanced (single-ended) audio sources (e.g. preamplifiers). This input 
can be activated with the 

BAL/UNBAL input selector

 (

12

). The 

UNBAL LED 

on

 

the

 

front panel display

 

(

7

)

 

will be lit. 

 
 

[ 15 ]

  BAL Input

 

 
To  connect  balanced  (differential)  audio  sources  (e.g.  preamplifiers).  This  input  can 
be  activated  with  the

  BAL/UNBAL  input  selector 

(

12

).

 

The

  BAL  LED 

on

 

the

 

front 

panel display

 

(

7

)

 

will be lit. 

  
 
PIN1 = Ground 
PIN2 =   
PIN3 = Signal - 
 
 
 
 
 
 

 
 

Содержание Monolog

Страница 1: ...OWNERS MANUAL MONAURAL POWER AMPLIFIER Monolog Monolog Monolog Monolog DOT BAR OFFSET TEMP 32dB 26dB 20dB BAL UNBAL TRIGGER 10V DC dB 13 16 19 22 25 28 31 34 37 40 10 7 5 3 1 0 1 2 3 Monolog...

Страница 2: ...chnical description 2 1 Safety considerations 2 2 Installation 2 3 Warranty and service 3 Operation 3 1 Front panel controls 3 2 Rear panel controls and connections 4 What if 4 1 nothing happens 4 2 t...

Страница 3: ...e pace and full dynamics of music signals The inherent optimal channel separation ensures a 3 dimensional soundstage and a holographic image of the musical event without any electronic limitation The...

Страница 4: ...sing These amplifiers are configured in fully differential mode with one amplifier driving one phase of the signal while the other is driving the opposite phase The load is connected between the two a...

Страница 5: ...Always power down the unit before connecting or disconnecting signal and or speaker cables Under all circumstances avoid electrically shorting the output connectors A short circuit may lead to immedi...

Страница 6: ...ications or tampering by non authorized personnel or third party Altered serial numbers automatically void any warranty Also excluded is transport damage accidents as well as any liability beyond the...

Страница 7: ...or destruction of the amplifier Once all connections are established always turn on the preamplifier first and the power amplifier last The power down sequence should be done in reverse order with th...

Страница 8: ...is turned on and functioning normally A flashing Status LED 1 indicates a malfunction Should the operating temperature of the unit reach its maximum permissible value the output relays will be automat...

Страница 9: ...lable The maximum allowable level at the amplifiers input is reached when the last LED is lit Any further level increase will overdrive he amplifier and potentially cause clipping of the output signal...

Страница 10: ...ealer distributor or Trigon Elektronik GmbH directly Since there may be a more serious problem at hand the unit must be verified by a qualified service technician 6 Gain LED 20dB 26dB and 32dB The pus...

Страница 11: ...that the signal cannot be recognized In this case it will be necessary to increase the volume setting at the preamplifier In 10V DC mode the Monolog amplifier will turn on when DC approx 4V to 10V is...

Страница 12: ...led mode only the Status LED 1 is active 11 GAIN selector Selects the voltage gain of the amplifier Three gain settings are available 20dB 26dB 32dB The selected value is displayed by the Gain LED 6 H...

Страница 13: ...r the preamplifier is switched on or off The selected automatic power mode is indicated by the TRIGGER 10V DC LED Display 8 Note If one of the AUTO power options is selected the main power switch on t...

Страница 14: ...r electrical ground CAUTION The load impedance must not be inferior to 2 Ohms 18 SPEAKON OUTPUT This socket may be used to connect the speaker with a SPEAKON plug This alternative hook up with an appr...

Страница 15: ...is connector outputs a 10V DC trigger voltage when a trigger signal is applied to the REMOTE 10V DC input connector 21 This feature allows to simultaneously turning on or off any number of Monolog pow...

Страница 16: ...g This may cause the Monolog s logic circuits to deactivate the output relays or to simply stop responding Switch off the power to the Monolog from the power switch located on the unit s front panel f...

Страница 17: ...al 100 V A weighted 140 V unweighted bal 150 V A weighted 220 V unweighted Signal to Noise ratio 103 dB at 1 Watt into 4 Ohms Noise floor 106 dB at 1 Watt into 4 Ohms Weight 23 5Kg Dimensions 300 x 16...

Отзывы: