If you are using this manual as a programming guide
after the initial installation, you may find the TABLE OF
CONTENTS useful in locating the particular
programming procedure you need.
This manual contains all the information required to
install and program the TRIGON HF-2. If you are using
this manual to install this unit, it is very important to
read all the sections in order.
You should read these instructions before you begin
installation. This will insure that everything is done
efficiently.
The Telalarm HF-2 is a multi-number emergency auto
dialer. Upon pressing the button, the HF-2 dials a
programmed telephone number. If the number dialed
is busy or does not answer, the HF-2 will hang up and
dial the next programmed number, up to a maximum
of 10. If the last programmed number is busy or does
not answer, the HF-2 will rollover and start the dialing
process again with the first phone number.
The HF-2 comes standard with one output relay. This
relay is pre programmed to close when the help button
is pressed in order to turn on a strobe light.
There are two Modes of Operation incorporated in the
HF-2:
1.
The Emergency Mode causes relay activation
at the moment the start button is pressed. This
mode is best suited for safety use when camera
and lighting control is desired.
2.
Optional Ring Down Mode:
When call call button is pressed, the HF-2 seizes
the telephone line and waits for the PBX to dial a
preprogrammed number. This call may only be
terminated by the called party.
A Site I.D. code feature provides for unit identification.
The Site I.D. code is a programmable four digit code
that is transmitted by the HF-2 when it receives a
command from the called party. This code, when
interpreted by a Trigon DTMF Decoder, will identify
the calling unit.
.
Figure 1
TRIGON
TRIGON ELECTRONICS
ORANGE CA.
CALL
HF-2
12"
4.2"
2.0"
Telephone Line-
Voice Grade 24 to 48V
22 AWG; Shielded
or Twisted,2 Conductor
Camera, Door or Gate
Secondary
Relay
Serial Printer
(18 AWG; Shielded, 3 Conductor)
Postal
Lock
Box
Primary
Output
Relay
Main Entrance
Power Cabling -
Shielded or Twisted,
2 Conductor,
18AWG up to 250'
16AWG up to 500'
Alarm
Shunt
Relay