background image

Page 4

T.A.C. 500

MOUNTING

MOUNTING

MOUNTING

MOUNTING

MOUNTING

Arrangements must be made for the installation of a
standard voice-grade telephone line (touch-tone or
rotary, telco or PBX  Port), as close to the unit mounting
location as possible.  The telephone company may
require the following information.

FCC Registration No..................1Z8898-62546-DI-T

Ringer Equivalence..............................................0.8B

Connector............................................Terminal Block

When selecting a mounting location, Trigon
recommends some shelter be provided from direct rain
and sunlight. An overhang is usually sufficient. If a
heater element is installed, be sure to use a bi-metal
thermal switch to prevent over-heating during the
summer months.

Pull the wiring through the access hole in the lower
portion of the back plate (Fig. 2).  Bolt the plate to the
surface through the four .312" mounting holes provided.
At this time, the wiring should NOT be  energized.

Note:  If used in extreme weather, a bead of silicon
sealant should be run around the outside top two thirds
of the unit, after the front case is secured.  (Fig. 2b).

WIRING

WIRING

WIRING

WIRING

WIRING

1. Use the wiring diagram on pg. 5  for wire connection

information.

2. Do not energize wires until installation is completed.

3. Do not power any other device from the T.A.C.’s

12 VAC transformer.  If a substitute transformer is
used, be sure it is rated 12 VAC, 20VA, UL Class 2
listed.  The 12 VAC input power wires should be
18AWG, 600V, insulated wire.  This should be
sufficient for distances up to 200 feet.

4. Ground the unit by attaching a separate 12 AWG

ground wire to the ground location on the terminal
block.  This ground wire should go to a grounding
rod or grounded metal conduit.

5. Trigon recommends that an EMI filter (Cornell-

Dubilier Model APF 1021 or equivalent) be mounted
between the 12 VAC transformer output and the unit.
EMI/RFI filters are available from Trigon.  Mount
the filter as close to the unit as possible.  Ground the
filter to the same point as unit ground.

6.  Shielded cable is recommended for both the power

and telephone cabling. Ground the cable's shield to
the same point as the unit and filter.  To avoid ground
loops, do not ground the shield at both ends.  Use
600V insulated wire for this installation.

7. Isolate the phoneline from 12 VAC power wires.

This will prevent 60 Hz hum from occurring on the
phoneline.  Use 22 AWG wire on Telco line run
distances of up to 2400 feet.  Consult the factory for
distances greater than 2400 feet.

8. Primary Relay is a dry contact, Form C type, rated

for 5 AMPS @ 30 VDC/ 250VAC.

9. The Shunt relay is a low-power (4 watt) reed relay.

It can be used for temporary alarm switch bypass,
video camera activation, etc.  The Shunt relay
activates with the output relay, and deactivates thirty
seconds after relay release.

10. (OPTIONAL)  Connect printer wiring to the RS-

232 port (Printer IN to RS-232 OUT, Printer BUSY
to RS-232 DSR, Printer COM to RS-232 COM).

11. If all wiring and grounding is completed, mount the

faceplate onto the backbox.

12. Apply power to the unit.

Figure 2b

Seal top 2/3 of case

 to mounting surface.

Side View

Figure 2

Figure 2b

5.60"

8 Holes
.312" Dia
marked as 'K'.

6 Holes
.875" Dia.
(knock-out)
marked as 'J'

BOTTOM

BACK

T.A.C.  500   Back &  Bottom Plate

2 x 3.0

2x 3.62

5.380

3.50

1.75

1.75

11.90

6.00

.875

3.50

1.05

2.10

4 x 2.75

J

J

J

J

J

J

K

K

K

K

K

K

K

K

Содержание T.A.C. 500

Страница 1: ...255 Glider Circle Corona CA 92880 800 842 7444 Info trigonelectronics com www TrigonElectronics com March 1 2004 INSTALLATION and OPERATION INSTRUCTIONS Multi Number Telephone Entry System T A C 500...

Страница 2: ...Deleting Telephone Numbers 7 Programming Entry Codes 7 Changing the Program Code 7 Deleting Entry Codes 7 Entering Access Cards 8 Deleting Cards 8 Programming Site ID Code 8 Programming Tamper Code 8...

Страница 3: ...ident then grants or denies access The T A C 500 has a capacity of up to 400 telephone numbers and up to 400 personal entry codes and is PBX compatible It is constructed for rugged outdoor use The T A...

Страница 4: ...e ground location on the terminal block This ground wire should go to a grounding rod or grounded metal conduit 5 Trigon recommends that an EMI filter Cornell Dubilier Model APF 1021 or equivalent be...

Страница 5: ...Page 5 T A C 500 Figure 3 WIRING DIAGRAM WIRING DIAGRAM WIRING DIAGRAM WIRING DIAGRAM WIRING DIAGRAM 1 2 3 4 5 6 7 8 9 10 Input Power Main Relay Gnd Alarm Shunt Relay Telco...

Страница 6: ...to answers This count is adjustable from 1 to 9 4 Enter the number that indicates the number of rings desired 3 For example Enter 1 for one 5 second interval Enter 2 for two 5 second intervals 10 seco...

Страница 7: ...ns for Programming Telephone Numbers and enter the new number in place of the old one The old number will be overwritten D Programming Entry Codes Entry Codes make it possible for the resident to ente...

Страница 8: ...ing the desired function code 5 Enter to exit Program Mode otherwise continue programming by entering the desired function code I Programming Site Identification Code In the case of multi unit install...

Страница 9: ...part of the week i e Tuesday through Friday Note Military time format 24 hour clock is used in clock programming To program Secondary Relay do the following 1 Unit must be in Program Mode see section...

Страница 10: ...keypad Otherwise the visitor may walk away leaving the unit active Shortly the loud off hook indicator tone from the telephone company will be heard for the remaining duration of the call length Latc...

Страница 11: ...nit When it answers choose from the following 1 Enter 0 for touch tone echo test Unit will echo any touch tone you send with your phone 2 Press to escape from this test 3 Enter 1 for memory test One t...

Страница 12: ...ice i e door strike RESIDENT CANNOT ACTIVATE STRIKE GATE 1 Tenant not pressing correct number on phone 2 Strike gate operator not wired correctly 3 Missing or incorrect power to strike or gate operato...

Страница 13: ...nit capacity cccc 2 rrrr Verify phone number for Resident Code rrrr none listed 3 Verify Clock MM DD YY hh mm d none installed 4 Verify Relay One Schedule hhmm hhmm d d not set 5 Verify Secondary rela...

Страница 14: ...ming Directly on keypad or remotely by DTMF tones Power 120VAC 12VAC 40VA Class 2 trans former included Relay Ratings Primary Relay 5 AMPS 30 VDC 250VAC 1 8 HP 120VAC Alarm Shunt Relay 250ma 12VAC Rel...

Страница 15: ...Page 15 T A C 500...

Страница 16: ...Page 16 T A C 500...

Отзывы: