background image

Page 1

CastleGate III

January 9, 2006

255 Glider Circle •  Corona, CA  92880

(951)  371-1730•  Facsimile (951) 371-2592

www.TrigonElectronics.com

  CastleGate III

Single Resident No-Phone-Charge System

INSTALLATION

AND

OPERATION INSTRUCTIONS

Содержание CastleGate III

Страница 1: ...Gate III January 9 2006 255 Glider Circle Corona CA 92880 951 371 1730 Facsimile 951 371 2592 www TrigonElectronics com CastleGate III Single Resident No Phone Charge System INSTALLATION AND OPERATION...

Страница 2: ...mming entry codes 6 Deleting entry codes 6 Changing programming code 6 Programming time of day clock 6 Programming relay 1 on time day 7 Programming relay 1 off time day 7 Programming relay 2 on time...

Страница 3: ...ELCO calls as well as calls from the front gate 2 The secondary mode is where the Castlegate III does not use the TELCO line but is wired directly from the gate to the residence In this mode either a...

Страница 4: ...to the ground location on the terminal block see wiring diagram Fig 3 This ground wire should go to a grounding rod or grounded metal conduit 4 Trigon recommends that an EMI filter Cornell Dubilier M...

Страница 5: ...22AWG Shielded or Twisted 2 Conductor Up to 2500 f t Telco In GRND Residence Out Bat t ery Back up Postal Lock Input Power Cabling 18AWG up to 250 16AWG up to 500 Shielded or Twisted 2 Conduct or 12VA...

Страница 6: ...p Enter the 4 digit entry code that you want to delete You will hear two beeps Erasure is complete If you hear four beeps here the code entered was not in the memory Repeat until all desired Entry Cod...

Страница 7: ...l disable that cycle timer Note Note Note Note Note Using 01 for a relay cycle timer will only guarantee cycle period ranging from 0 to 1 second and may not produce an acceptable pulse Use 02 seconds...

Страница 8: ...access the resident can return to their outside call by again pressing the key on their telephone B Call waiting B Call waiting B Call waiting B Call waiting B Call waiting In the case where you are u...

Страница 9: ...9 WXY 0 Latch Hold Relay 1 To release press 5 and hang up Latch Relay 1 Released when resident s telephone is hung up Latch Hold Relay 2 To release press 8 and hang up Latch Relay 2 Released when res...

Страница 10: ...LOSES MEMORY LOSES MEMORY 1 Electrical noise on power line Install EMI RFI filter 2 Excessive electrical noise from strike Use low current strike 3 Unit transformer shared with another device i e doo...