TMA44 Audio Panel Installation Manual
7 November 2017
01849-00 Issue
AB
______________________
Page 34
Trig Avionics Limited
Procedures for David Clark PTT
1. Unscrew the round black plastic cover from the jack.
2. Connect the joined black wires to the red wire.
3. Replace the round black plastic cover.
Procedures for Telex PT-200
1. Unscrew the round black plastic cover from the jack.
2. Cut the red wire in the middle of the wire.
3. Strip both ends of the insulation.
4. Solder the two ends to the ground lug to the PTT jack.
5. Replace the round black plastic cover.
Procedures for Telex PT-300
1. Unscrew the round black plastic cover from the plug jack.
2. Remove the heat shrink material from the joined black wires.
3. Solder these two wires to the lug that has a white wire already soldered to it.
4. Replace the round black plastic cover