Failure to clean sink waste pipe line
may result in waste pipe blockage.
1. Remove trap.
2. With drain auger, clear away all
hardened waste material in
horizontal drain line running from
drain trap to main pipe.
PERSONAL INJURY
To avoid personal injury, do not position your head or body under
disposer; the unit could fall during installation.
Clear any objects from inside the disposer grind chamber before
mounting the disposer to the sink.
1. Position disposer with three mounting tabs(1) aligned in position to
slideover mounting tracks (2).
2.Lift disposer, insert top end (mounting gasket) into mounting assembly,
and turn lower mounting ring to right (with wrenchette or adjustable
pliers)until mounting tabs lock over ridges (3) on mounting ring
tracks.Make sure all three mounting tabs are locked over ridges.
Disposer will now hang by itself.
3. Run water into sink, then check for leaks.
4. When installing this product, please make sure the reset switch can be
easily touched, and there is no object block which may affect the later
operation
8.DISHWASHER CONNECTION
NOTE:
If the dishwasher connection is made without removing the plug.
the dishwasher may overflow. (Connections must comply with local plum
bing codes.)
①
Remove the connecting plug(A) of dish washer, and replace the
dishwasher connecting(B).
②
Connect the dish washer drain pipe to the dishwasher connecting
If you have a sink overflow, it should be connected to the overflow
inlet on the tailpipe .
Install the drain pipe connecting(A) on
to the disposer,put the rubber
gasket(B) into the drain pipe(C). After
that, install the discharge tube on to
the drain pipe connecting(A).
If you are not thoroughly familiar with electric power,contact a qualified
electrician to connect disposer to electrical circuit.
If three-prong, earth (grounded)plug is used,plug must be inserted into
three-hole, earth (grounded) receptacle.
Do not modify plug provided with unit (if applicable).
Improper connection of equipment earth (grounded) conductor can
result in electric shock.
All wiring must comply with local electrical codes.
Do not attach earth wire (ground wire) to gas supply pipe.
Do not reconnect electrical current at main service panel until proper
earth (grounded) outlets are installed.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified-persons in order to
avoid a hazard.
9.ATTACH DISCHARGE TUBE TO WASTE DRAIN PIPE
6.CLEAN SINK WASTE PIPE
7.CONNECT DISPOSER TO MOUNTING ASSEMBLY
CAUTION
ELECTRICAL SHOCK
To avoid electrical shock, disconnect power before installing or servicing
disposer.
DANGER
10.CONNECT DISPOSER TO ELECTRICAL SUPPLY
-3-
A
B