Data sheet 09/18-CO104-2
1. Standards
UL 8750
CSA C22.2
FCC Part 15
Product not designed for European Economic Area.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference
that may cause undesired operation.
2. Thermal details and life-time
2.1 Expected life-time
3. Installation / wiring
3.1 Circuit diagram
LC 48V DC-STR UNV FO lp
48
V
PRI
120/277 V
L
N
0/50/60 Hz
+
–
~
~
LMI 48
V
48V
input
LMI 48
V
48V
input
BRIDGE 0-10V
PLC DC STR lp
+
–
0-10V (+)
0-10V (–)
0 – 10 V
Dimmer
48
V
3.2 Wiring type and cross section
The wiring can be in stranded wires with ferrules or solid with a cross section
of 0.2–1.5 mm² / 24 – 16 AWG.
Strip 8.5–9.5 mm /
3/8 inch
of insulation from the cables to ensure perfect
operation of the push-wire terminals.
Use one wire for each terminal connector only.
3.3 Loose wiring
Press down the “push button” and remove the cable from front.
8.5 – 9.5 mm / 0.33 – 0.37 inch
wire preparation:
0.2 – 1.5 mm² / 24 – 16 AWG
3.5 Hot plug-in
BRIDGE is suitable for hot plug-in.
Devices will be switched off shortly for fadetime configuration at hot plug-in.
Maximum number of LMI LED Drivers is limited by 20.
1.1 Glow wire test
according to EN 61347-1 with increased temperature of 850 °C passed.
Life-time is limited by DC power supply.
Max. tc point temperature must not be exceeded.
To use dimming functionality use dimmable LMI LED drivers with “DIM” in