background image

WWW.TRIDENTPROTECTS.COM   

 

 

 

 

 

 

        866-951-4293 

SURFACE PREPARATION 

 

Test First:  

Test first on a small inconspicuous area to determine suitability and if desired results are achievable with this product 

on your specific surface. 

 

Clean Surface:  

Surface should be thoroughly cleaned and prepared with Trident’s cleaners. It should be free of oil, dust, loose  

material, and previously applied sealer other than Trident’s Cyclone sealer. Kill and remove growth of any mold, mildew, fungus   
or algae. Thoroughly rinse all cleaner residue prior to sealing.   

 

Allow surface to dry for a minimum of 24 hours 

after cleaning and/or rain before joint sand installation or sealer application. 

 

Joint Stabilization Preparation:  

Paver joints should be no more than 3/4” wide and filled with dry correctly graded joint sand that 

meets ASTM C144 standard. Compact surface with vibratory roller or compactor after sweeping sand into joints to minimize air 
voids. Top level of sand should be 1/8” below the bottom of chamfer edge or on non-chamfered surfaces 1/8” down from top of 
surface.

 

 

 

Prior to sealing, use a 

leaf blower

 

to remove dust, debris and fine sand particles

 from the surface.

 

 

Cover/Protect 

nearby landscape, vehicles and buildings from overspray during application.

 

APPLICATION CONDITIONS

 

 

Apply when day and night temperatures are between 40°F - 95°F. 

 

Allow surface to dry for a minimum of 24 hours after cleaning and/or rain before sealer application. 

 

Avoid windy conditions to keep sealer spray from drifting. 

 

NO pre-blending or mixing required. 

DO NOT DILUTE. 

 

Excessive applications can cause surface to become slippery. Some surfaces may require an anti-slip additive to increase friction. 

APPLICATION TOOLS 

 

Low pressure, high volume sprayer such as an airless sprayer or hand held pump-up sprayer   

 

Slit foam roller 

 

Foam squeegee for joint stabilization 

APPLICATION INSTRUCTIONS 

Cyclone is designed for a one-coat application but if desired an additional light spray coat can be applied only after the first         
application has dried to the touch.  

Spray & Back Roll Application (no joint stabilization):   

 

To apply sealer, hold sprayer nozzle perpendicular to the surface, spray and overlap each spray pass.   

 

Before product dries

, back roll with a foam roller to eliminate any pooling and to even out sealer. 

 

Flood Coat & Squeegee Application for Joint Stabilization:  

 

Follow coverage guidelines for joint stabilization.

 

 

Spray sealer to flood joints ensuring proper sand penetration for stabilization. 

 

 

Use a foam squeegee to direct excess sealer into the joints. On an uneven surface, it is recommended to then back roll with a foam 
roller to even out the sealer and eliminate pooling. 

DRY TIME 

 

Surface will be dry to the touch in 60 minutes assuming 65-85°F. Low surface or air temperature will extend dry times.  

 

Protect the surface from dust, rain, condensation, and traffic while drying.  

 

Area can be open to foot & vehicular traffic in 24 hours depending on site conditions. 

 

TECHNICAL DATA SHEET  

CYCLONE 

 

Cyclone |  Page 2 | TDS 113 | Revised Date:  5.1.2020 

Содержание CYCLONE

Страница 1: ...f desired a light second coat may be applied after the first coat has dried to the touch COVERAGE PER GALLON APPLICATION SQ FEET SQ METERS Sealing With Joint Stabilization 80 120 7 4 11 1 Sealing Only Without Joint Stabilization 150 250 13 9 23 2 PURPOSE PERFORM A TEST IN A SMALL AREA TO VERIFY PERFORMANCE AND APPEARANCE BEFORE APPLYING Due to the variability and physical make up of natural stone ...

Страница 2: ...fore sealer application Avoid windy conditions to keep sealer spray from drifting NO pre blending or mixing required DO NOT DILUTE Excessive applications can cause surface to become slippery Some surfaces may require an anti slip additive to increase friction APPLICATION TOOLS Low pressure high volume sprayer such as an airless sprayer or hand held pump up sprayer Slit foam roller Foam squeegee fo...

Страница 3: ...hly rinse all cleaner off the surface before sealing RE APPLICATION Re application may need to be carried out every 2 3 years depending on the type of surface and environmental site conditions PACKAGING 5 Gallon Pails 55 Gallon Drums 275 Gallon Totes Store in a cool well ventilated place Do not allow to freeze SHELF LIFE 2 years when unopened and properly stored VOC CONTENT 99 g L CYCLONE TECHNICA...

Страница 4: ... IL 60174 866 951 4293 www tridentprotects com TECHNICAL DATA SHEET CYCLONE Cyclone Page 4 TDS 113 Revised Date 5 1 2020 Protect sealer from freezing and store in a cool place when not in use In winter keep in heated area This sealer is not recommended for marble granite ceramic tile and polished honed or high gloss surfaces as they do not absorb the sealer A test area is ALWAYS recommended to det...