STEP-UP & INSTALLATION
Trico Spectrum Oil Storage Systems come almost fully assembled. They are meant to store petroleum-
based lubricants in a clean, orderly, organized, space saving method. The system only requires the
Watchdog Extreme Humidity Desiccant Breathers attached, the correct electrical outlet to plug the
motor in, and to mount the On/Off switch to make the system usable. If more than 2 tanks were
purchased, installing additional manifold valves, and attaching hoses for the additional tanks will need to
be accomplished as well.
Note:
Personal Protective Equipment (“PPE”) should be worn when installing,
operating, and maintaining this system.
Time, Materials, Personnel, and Tool Requirements
•
Only one person is need to complete installation.
•
Assembly Time is approximately 15 minutes for a standalone Pump Stack unit, an additional 30
minutes required for each add-on Storage Stack unit.
•
Electrical hook-ups and installation should be completed by your authorized electrical personal
in accordance with all local, federal, and building regulations.
•
A narrow, 22” maximum width, hand pallet truck rated for at least 2,000 lbs can be used to
move each unit into its final position.
•
A pipe wrench for 2” pipes is needed for adding additional Storage Stack units to the Tank
Manifold on the Pump Stack unit.
•
All fittings already assembled on the system are tightened with thread sealant.
•
5/16 nut driver, or a crimp clamp tool, for tightening hose clamps.
•
Adjustable crescent wrench for hex plugs on manifold.
System Placement Determination
•
The system is recommended for indoor use only.
•
The system must be installed on a flat, level surface. The surface must have sufficient load-
bearing capacity to support the total system (each 2-tank Stack weighs 2,000 lbs filled with
lubricant).
•
The system can be mounted permanently to the floor using the mounting holes in the Spill
Containment. Mounting will not be covered in this manual and will be the responsibility of the
end user to mount using the correct hardware.
•
The electric motor on the Pump Stack has a full load amperage of 17.2A and a separate 20 Amp
circuit is recommended for each Pump Stack. The power cord on the motor is approximately 14
feet in length.
•
There should be a minimum of 12” of space from the back of the Spill Containment. This
provides room for the hoses. More room may be required behind the units for maintenance and
easier access to the tank shut-off valves, up to 24”.