Read Instructions Before Installing

To Install:

Product Ordering:

Replacement Parts:

See Reverse Side For Specific Instructions On Installing The Closed System

TRICO CORP.  1235 HICKORY STREET, PEWAUKEE, WI 53072  TEL. (262) 691-9336  FAX (262) 691-2576

www.tricocorp.com

69509     01/15

Loosen set screw on reservoir assembly. Remove reservoir 
and put aside (Fig. 2).

2.

Verify that there are no contaminants or noticeable particles 
in the CLOSED SYSTEM or bearing housing.

3.

Tighten supplied plug in side or bottom fluid port, sealant is 
not  necessary  on  plug.  If  using  side  fluid  port  to  connect 
CLOSED SYSTEM to the bearing housing, tighten plug in 
bottom  fluid  port.  If  using  bottom  fluid  port  to  connect 
CLOSED SYSTEM to the bearing housing, tighten plug in 
side fluid port (Fig. 2).

4.

Apply  pipe  thread  sealant  to  a  1/8"NPT  x  1/4"OD  male 
connector and tighten it into the vent port on the CLOSED 
SYSTEM.

6.

Apply  pipe  thread  sealant  to  a  1/8"NPT  x  1/4"OD  male 
connector  and  tighten  it  into  the  vent  port  on  the  bearing 
housing.

7.

Connect a section of 1/4"O.D. copper or nylon tubing to the 
1/8" NPT connectors. This will serve as the vent line (fig. 3).

8.

Fill the bearing chamber through the main body of the 
CLOSED SYSTEM until it reaches just below the optimum 
fluid level visible in the sight. Use the reservoir to feed oil 
to the proper level.

10.

Place thumb over reservoir spout, invert, and insert the spout 
into the main body of CLOSED SYSTEM until upper casting 
bottoms out on the collar.

12.

Oil may drain out of the reservoir and into bearing housing. 
Secure set screws on upper casting.

13.

Start  up  machine  and  verify  proper  oil  level  is  being 
maintained.

14.

C

LOSED 

S

YSTEM

ITEM #

1

2

3

4

5

6

DESCRIPTION

4 Ounce Reservoir Assy.

8 Ounce Reservoir Assy.

16 Ounce Reservoir Assy

Set Screw

O-Ring 1.375" ID x .062 CS

Hex Socket Screw

Sight Gauge

¼" Square Plug

CATOLOG #

26113R

26115R

26120R

10267R

12829

10262R

26121R

10321R

With Sight Gauge / Constant Level Oiler

Adjust the collar to the desired fluid level. Bottom of collar 
indicates  fluid  level  (see  back  side  for  dimensions  from 
centerline of side port to bottom of collar.)

9.

Reservoir

Set screw

Collar

Fluid Port

Fig. 2

Bottom and Side

C

LOSED 

S

YSTEM

With Sight Gauge / Constant Level Oiler

Vent Line

Fig. 3

1

3

4

5

6

2

0.090” MIN.
0.840” MAX.

3/4” RANGE
OF ADJUSTMENT

MOUNTING DIMENSIONS

5

DO NOT install or remove the CLOSED SYSTEM with or by use of the reservoir assembly.

DO NOT use the CLOSED SYSTEM for stepping, standing, or heavy loading as these actions could 
cause a change in oil level settings and may cause leaks.

DO remove the reservoir from the CLOSED SYSTEM during installation and removal.  

DO use the bottom fluid port if oil level is set at the lowest level for optimal oil feeding.

Apply pipe thread sealant to both ends of a 1/4" NPT male 
nipple.  Tighten  nipple  in  remaining  fluid  port  and  bearing 
housing. If bottom fluid port is remaining, an elbow may need 
to be used. The CLOSED SYSTEM should be parallel to the 
bearing housing in a vertical position within ±1º (Fig. 3).

5.

Prior to installing the CLOSED SYSTEM, shaft rotation direction must be determined, typically 
indicated by an arrow on the casting of the equipment. Install oiler on the side of the equipment 
facing the direction of shaft rotation to prevent misfeeding of the oiler (see Fig 1).

1.

Using a funnel, fill the reservoir.

11.

Fig. 1

Direction of shaft rotation