Ignition HT Spark

Spark Generator

Ispra Control's BF 50046 - 230-240V   0.6 YA   T 120

Spark Gap

Fixed

OVERALL DIMENSIONS

Width:

580 mm.

Depth:

500 mm.

Height:

88 mm.

Burner

Dia. Tap By-pass

1/100 mm

Auxiliary

28

Semi-rapid

32

Rapid

40

Aeration adjustment none

Instructions for the Installer

CUT OUT DIMENSIONS

Width:

550 mm.

Depth:

470 mm.

Thickness: 30 mm.

BURNER

RAPID

SEMI-RAPID

AUXILIARY

(large)

(medium)

(small)

POSITION

MAX

MIN

MAX

MIN

MAX

MIN

 NOMINAL THERMAL
 POWER                        kW

3.0

0.65

2.0

0.45

1.0

0.33

 NOMINAL FLOW
 RATE                         m

3

/h

0.286

0.057

0.190

0.038

0.095

0.028

 NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

 NOMINAL THERMAL
 POWER                        kW

2.8

0.65

2.0

0.45

1.0

0.33

 NOMINAL FLOW
 RATE                            g/h

202

43.5

144

29

72

21,5

 NOZZLE REFERENCE

86

40

71

32

50

28

NATURAL GAS

20 mbar

TYPE OF

GAS

CHARACTERISTICS

LPG GAS

28-30/37 mbar

1/100 mm

1/100 mm

VALUE = 49.92 MJ/Kg

VALUE = 37.78 MJ/m

3

Ws - 50.7 MJ/ m

3

Rear Left Burner (semi rapid)
Heat Input

2.0 kW (6824 BTU/HR)

Front Left Burner (rapid)
Heat Input

3.0 kW Natural Gas (10236 BTU/HR)

                                   2.8 kW L.P.G. (9554 BTU/HR)

SUPPLY CONNECTIONS

Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:
230-240V 50Hz supply, 3 core flexible cable with
non rewireable plug fitted with a 3 amp cartridge
fuse.

This appliance complies with the EEC Directive No
89/336, concerning suppression of radio electrical
interference.

CLASS APPLIANCE: 3

APPLIANCE
CATEGORY: II2H3+

APPLIANCE
GAS SUPPLY: Natural gas G20 / 20mbar

Rear Right Burner (semi rapid)
Heat Input

2.0 kW (6824 BTU/HR)

Front Right Burner (auxiliary)
Heat Input

1.0 kW (3412 BTU/HR)

Содержание TBG 640

Страница 1: ...2 INSTRUCTION BOOKLET GAS HOB MODEL TBG 640 Please read this instruction booklet before using the appliance ...

Страница 2: ......

Страница 3: ...s a continuous air supply keeping air vents in good condition or installing a cooker hood with a venting hose When using the hob for a long period time the ventilation should be improved by opening a window or increasing the extractor speed Do not use this hob if it is in contact with water Do not operate the hob with wet hands Ensure the control knobs are in the OFF position when not in use When ...

Страница 4: ...C current edition Contents For the Installer Technical Data Page 12 Important Safety Requirements Page 13 Installation Page 14 Gas Connection Page 14 Building In Page 15 Electrical Connection Page 16 Wiring Diagram Page 17 Fault Finding Page 18 Commissioning Page 20 Conversion from natural gas to LPG Page 21 Guide to Use the instructions The following symbols will be found in the text to guide you...

Страница 5: ... Hob INSTALLATION Any gas installation must be carried out by a registered CORGI installer and in accordance with existing rules and regulations The relevant instructions are to be found in the second section of this manual Please ensure that once the hob is installed it is easily accessible for the engineer in the event of a breakdown WHEN THE HOB IS FIRST INSTALLED Once the hob has been installe...

Страница 6: ...hould only use pots and pans with a flat bottom fitting the size of the burner used see table If you use a saucepan which is smaller than the recommended size the flame will spread beyond the bottom of the vessel causing the handle to overheat As soon as a liquid starts boiling turn down the flame so that it will barely keep the liquid simmering Take care when frying food in hot oil or fat as the ...

Страница 7: ...overs Should the hob top become heavily soiled it is recommended that a cleaning product such as Hob Brite or Bar Keepers Friend is used Pan Supports The pan supports are dishwasher proof If washing them by hand take care when drying them as the enamelling process occasionally leaves rough edges If necessary remove stubborn stains using a paste cleaner The Burners The burner caps and crowns can be...

Страница 8: ...all out an engineer to a fault listed below or to repair a fault caused by incorrect use or installation a charge will be made even if the appliance is under guarantee If after all these checks your hob still does not operate correctly contact your local Tricity Bendix Service Force Centre When you contact them they will need the following information 1 Your name address and post code 2 Your telep...

Страница 9: ... available outside these hours in which case a premium will be charged Exclusions This guarantee does not cover Damage or calls resulting from transportation improper use or neglect the replacement of any light bulbs or removable parts of glass or plastic Costs incurred for calls to put right an appliance which is improperly installed or calls to appliance outside the United Kingdom Appliances fou...

Страница 10: ...oman Ridge Road Sheffield S9 1GB NORTH WEST BIRKENHEAD 1 Kelvin Park M11 Dock Road Birkenhead L41 1LT CARLISLE Unit 8 M10 South John Street Carlisle CA2 5AJ ISLE OF MAN South Quay Ind Estate M64 Douglas Isle of Man LIVERPOOL Unit 1 M15 Honeys Green Precinct Honeys Green Lane Liverpool L12 9JH MANCHESTER Unit 30 Oakhill Trading M09 Estate Devonshire Road Worsley Manchester M28 3PT PRESTON Unit 250 ...

Страница 11: ...ondon SE9 4EW ENFIELD 284 Alma Road M49 Enfield London EN3 7BB GRAVESEND Unit B4 M57 Imperial Business Estate Gravesend Kent DA11 0DL HARPENDEN Unit 4 M46 Riverside Estate Coldharbour Lane Harpenden AL5 4UN LETCHWORTH 16 17 Woodsite Ind Est M50 Works Road Letchworth Herts SG6 1LA LONDON 2 4 Royal Lane M76 Yiewsley West Drayton Middlesex UB7 8DL MAIDENHEAD Reform Road M60 Maidenhead Berkshire SL6 8...

Страница 12: ...TE g h 202 43 5 144 29 72 21 5 NOZZLE REFERENCE 86 40 71 32 50 28 NATURAL GAS 20 mbar TYPE OF GAS CHARACTERISTICS LPG GAS 28 30 37 mbar 1 100 mm 1 100 mm VALUE 49 92 MJ Kg VALUE 37 78 MJ m 3 Ws 50 7 MJ m 3 Rear Left Burner semi rapid Heat Input 2 0 kW 6824 BTU HR Front Left Burner rapid Heat Input 3 0 kW Natural Gas 10236 BTU HR 2 8 kW L P G 9554 BTU HR SUPPLY CONNECTIONS Gas RC 1 2 inch 1 2 inch ...

Страница 13: ...fuel burning appliances in the same room B S 5440 Part 2 Current Edition should be consulted to determine the requisite air vent requirements Location The hob may be located in a kitchen a kitchen diner or bed sitting room but not in a bathroom or shower room Before making the cut out in the worktop ensure that there is a minimum distance of 55 mm between the rear edge of the hob and the wall A mi...

Страница 14: ... thorough leak test is carried out on the hob and installation Ensure that the main connection pipe does not exert any strain on the hob Installation IMPORTANT This hob must be installed by qualified personnel to the relevant British Standards Any gas installation must be carried out by a registered CORGI installer The manufacturer will not accept liability should the above instructions or any of ...

Страница 15: ... diagram 3 The panel fitted under the hob a should be easily removable to allow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections It is also recommended to carry out the electrical connection to the hob as shown in diagrams 1 and 2 FO 0199 a Fitting the Hob into the worktop Carry out the building in of the hob as follows put the seals sup...

Страница 16: ...arth wire to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green and yellow Connect the blue neutral wire to the terminal in the plug which is marked with the letter N or coloured black Connect the brown live wire to the terminal in the plug which is marked with the letter L or coloured red NOTE The earth wire should be about 2 cm longer than the live a...

Страница 17: ...17 B L N 0 1 2 3 4 220 240 A Wiring diagram A IGNITOR SWITCH B IGNITOR UNIT ...

Страница 18: ...ould it be found that the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a result of local burning arcing but no fault could be found under test However a detailed visual inspection should reveal evidence of burning around the fault START Isol...

Страница 19: ... simmer adjusted Light burner manually Check gas supply at burner Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check for bre...

Страница 20: ...p see diagram The b type has the adjustment screw located down the centre of the gas tap control shaft The c type has the by pass screw located to the side of the gas tap itself To adjust use a thin bladed screwdriver and turn the adjustment screw until the flame is steady and does not extinguish when the knob is turned from MIN to MAX Repeat this procedure for all burners Pressure Testing Remove ...

Страница 21: ...s burner caps rings crowns and control knobs With the aid of a 7mm box spanner the burner injectors can then be unscrewed and replaced by the appropriate LPG injectors see table on page 12 TO ADJUST THE GAS RATE With the aid of a thin bladed screwdriver completely tighten down the by pass adjustment screw which is located down the centre of the gas tap control shaft Upon completion stick the repla...

Страница 22: ......

Отзывы: