Installation instructions
Important – safety requirements
This appliance is suitable for installing on gas
I2ELL and I2E.
To install the appliance on gas supply of I2E all
injectors must be changed to those supplied
with the appliance.
INJECTOR MARKING
I2ELL
INJECTOR MARKING
I2E
RHF
074
070
RHR
110
096
LHF
110
096
LHR
133
119
Grill
137
120
Oven
112
99
Check that this model is suitable for the type of
supply available. This appliance must be
installed and or serviced by a competent person
in accordance with the local Gas
Safety/Electrical requirements.
WARNING!
This appliance must be installed by a
qualified electrician / competent person.
Safety may be impaired if installation is not
carried out in accordance with these
instructions.
Before connecting the appliance make sure
that the voltage of your electricity supply is
the same as that indicated on the rating
plate. This is situated on the lower front
frame of the appliance and can be seen upon
opening the door. Alternatively the rating
plate may also be found on the back or top
of some models (where applicable).
Do not alter the electrical circuitry of this
appliance.
Provision for ventilation
•
This appliance is not connected to a
combustion products evacuation device. It
shall be installed and connected in
accordance with the current installation
regulations. Particular attention shall be
given to the relevant requirements regarding
ventilation.
•
The room containing the appliance should
have an air supply in accordance with local
requirements. All rooms require an
openable window or equivalent and some
rooms will require a permanent vent as well.
For room volumes up to 5m
3
an air vent of
100cm
2
is required: for room volumes
between 5m
3
and 10m
3
an air vent of 50cm
2
is required. If the room has a door that opens
directly to the outside, no air vent is required.
For room volumes that exceed 11m
3
no air
vent is required. If there are other fuel
burning appliances in the same room, local
requirements should be consulted to
determine the requisite air vent
requirements.
•
Prolonged intensive use of the appliance
may call for additional ventilation, for
example opening a window, or more
effective ventilation, for example increasing
the level of mechanical ventilation where
present.