Health & Safety precautions 

 

This manual contains basic information on the installation, operation and maintenance of the 
Tricel  Puraflo wastewater treatment system.  For  this  reason,  it  is  essential  that  these 
instructions are carefully read and understood before installation or commissioning by both 
the installation crew as well as those responsible for the operation and maintenance of the 
system. 

This manual should be readily available at the location of the system. It is the responsibility of the 
homeowner to  ensure  that  the  wastewater  treatment  system  is  operated  and  maintained 
correctly and in a safe manner at all times. As safety and security are of vital importance, the 
following aspects are critical: 

1.1

 

General 

 

Ensure that all the information contained in this manual is adhered to at all times. 

 

Treated wastewater is not suitable for human consumption. It is unhealthy for humans, 
pets, and wildlife to drink or come in contact with surface or ground water contaminated 
with sewage. 

 

It is important that locks are fitted to the lid to prevent accidental access. 

 

Never enter a tank, unless qualified to do so. 

 

Naked flames shall not be used in the vicinity of the tank due to the danger of combustion. 

 

The manhole covers shall never be left off an unattended tank. Always lock the covers 

of the plant when work is completed. 

 

Sewage and sewage effluent can carry micro-organisms and gases harmful to human 

health. 

 

Any person carrying out work on the wastewater treatment system  must be 

appropriately trained.  

 

Suitable protective clothing; including waterproof/abrasion-resistant gloves, overalls, 

safety footwear, eye, ear and respiratory protection, goggles (face visors are particularly 

effective against splashes) should be worn at all times. All protective clothing must be 

in good condition and be fit for its intended purpose.  

 

Always remove contaminated clothing and protective equipment after working with 

wastewater treatment plants. Wash hands and face prior to eating, drinking or smoking. 

 

Wastewater treatment plants contain very low levels of oxygen. Hydrogen sulphide, 

methane, carbon dioxide and other  life-threatening gases are also present. Tanks 

have manholes covers to provide access to the tank only in times of cleaning and 

inspecting the tank from outside. The manhole covers must always be in place and 

secure. 

 

Keep vehicles and other heavy equipment away from the wastewater treatment plant 
and percolation area. 

 

Erect a safety barrier around open manholes to prevent anyone from accidently falling 
down the manholes. 

 

Keep children away from the septic system when it is being worked on. 

 

Do not smoke near wastewater treatment plants. Combustible gases could be present 

and cause an explosion.  

 

Contact a plumber or other qualified person if you smell 'sewer gases'. They can identify 

the source and correct it immediately. 

 

The sewage treatment process uses many beneficial microorganisms, like bacteria, in 

the treatment process. However, the plant also contains harmful bacteria, viruses and 

disease-organisms. Liquid and solid contents of the septic system are capable of causing 

infectious diseases. 

Содержание Puraflo 1-50

Страница 1: ...1 124 Rev 4 Jan 2019 Tricel Puraflo 1 50 Installation Wastewater Treatment Plants Engineering a green future...

Страница 2: ...3 Tricel Puraflo systems 1 11PE max 4 modules 6 2 3 1 Puraflo module installation step by step guide 6 2 3 2 Septic tank effluent filter installation secondary treatment only 10 2 4 Tricel Puraflo sy...

Страница 3: ...e wastewater treatment system must be appropriately trained Suitable protective clothing including waterproof abrasion resistantgloves overalls safetyfootwear eye earandrespiratoryprotection goggles f...

Страница 4: ...udgingand thereforethisshallneverbe donealone A wastewater treatment system that fails to fully treat sewage due to poor maintenance or overloading may allow excess nutrients phosphorus and nitrogen t...

Страница 5: ...cel Puraflo modules Suitably sized equipment will be required to excavate the hole and to lift the Tricel Puraflo system into place minimum 6 ton machine The Tricel Puraflo system should not be instal...

Страница 6: ...uidelines 6 Install pump chamber as per manufacturer s guidelines Install Puraflo Modules 7 Excavate a hole that will allow for a minimum 275mm gravel base beneath the Puraflo modules taking note of w...

Страница 7: ...the rising main must be dug from the pump chamber water treatment plant to the Puraflo modules inlet assembly We recommend a 300mm wide trench with a 650mm depth The rising main must be surrounded by...

Страница 8: ...dge fits under the Tricel Puraflo modules and into the V shape between the modules 16 Install the remaining outer PVC pipes and connect them into sampling chamber Once the pipework has been connected...

Страница 9: ...should be connected to this inlet assembly in single zone systems The rising main must be connected to the inlet of the indexing valve in multi zone systems The following images show the completed in...

Страница 10: ...t only Secondary treatment Tricel Puraflo systems require an effluent filter be installed at the outlet of the septic tank o On sites in which complete secondary treatment systems i e septic tank AND...

Страница 11: ...of the Vento septic tank 2 Glue the 200mm length 110mm 4 diameter sewer pipe to the outlet of Vento septic tank 3 Fit the euro reducer into the effluent filter Apply PVC sealant around the end of the...

Страница 12: ...200mm 110mm pipe and push the effluent filter onto the pipe Secure the effluent filter using a self tapping screw in the location indicated by the arrow 3 To facilitate access to the effluent filter w...

Страница 13: ...the pump chamber and the Puraflo modules 2 4 1 Indexing valve There are two types of indexing valve The indexing valve supplied is determined by the number of zones in the Tricel Puraflo system o 6 o...

Страница 14: ...ve 2 Threaded pipe supplied with valve 3 Union nut 4 Union end 5 50mm length of 32mm pipe 6 40 32mm reducing bush 7 40mm elbow Note The elbow object 7 above can be orientated to suit the installation...

Страница 15: ...bottom of the distribution box to suit the site conditions 5 Place the indexing valve into the distribution box connect the outlet pipes to Puraflo modules and inlet pipe from the pump chamber to the...

Страница 16: ...n of The power supply SWA cable s must be suitably sized and comply with all national regulations and requirements The sizing of the cable is the responsibility of a qualified electrician A qualified...

Страница 17: ...vice technician It is important Tricel commission the Tricel Puraflo system to verify that the system has been installed correctly and ensure that the Tricel Puraflo will achieve the required treatmen...

Страница 18: ...18 This page is intentionally left blank...

Страница 19: ...19 This page is intentionally left blank...

Страница 20: ...ary 221361 1 62 4050 33P Puraflo Secondary 221349 1 98 4950 33P Puraflo Tertiary 221362 1 98 4950 42P Puraflo Secondary 221350 2 52 6300 42P Puraflo Tertiary 221363 2 52 6300 45P Puraflo Secondary 221...

Отзывы: