32
7
Disposal of treated water
Dispose of the treated wastewater from the Tricel Novo as per guidelines from the planning
regulations issued by your local authority.
8
Maintenance
Warning
Any maintenance carried out inside the tank represents a confined space. Therefore, the
maintenance person must be suitably trained to work in confined spaces. Sewage and sewage
effluent can carry micro-organisms and gases harmful to human health. Any person carrying
out maintenance of the plant must be trained approprately. Wear suitable protection
equipment including gloves, goggles, etc. at all times. Always remove contaminated clothing
and protective equipment after completion of work. Wash hands and face before eating,
drinking or smoking. Please refer to section 1
‘Health & Safety Pre
cautions
.’
A certain amount of plant maintenance is required on an on-going basis to ensure that the plant
is working correctly, and this is the responsibility of the homeowner.
8.1
Regular maintenance
•
The vent around the base of the blower housing guarantees a fresh supply of air to the air
blower. All vents should be checked to make sure they are not blocked or obscured.
•
The vent under the de-sludging cover allows gas to escape and stops the tank from becoming
pressurized.
•
Ensure the air blower is working by listening for a gentle hum when standing beside the plant.
•
The inlet and outlet should be inspected and rodded to remove any blockages if necessary.
8.2
Annual maintenance
•
The Tricel Novo will require a full service (available from your supplier) every year to
guarantee the maintenance of the efficiency of the plant. You must accommodate service
personell with clear access to the tank.
8.3
Annual service (available from your supplier)
During routine servicing, the service technician will perform a series of checks and procedures:
Checks:
•
The air-diffuser is monitored to check for sufficient dispersion of air.
•
The sludge return system is functioning correctly.
•
The covers and locks are in place and good condition.
•
General appearance and condition of the treatment plant are good.
Содержание Novo UK10
Страница 1: ...0 106 Rev 11 Dec 2017 Tricel Novo UK6 50 Wastewater Treatment Plants Engineering a green future...
Страница 4: ...3...
Страница 5: ...4...
Страница 10: ...9...
Страница 11: ...10...
Страница 26: ...25 5 11 1 Electrical Diagrams 5 11 1 1 Tricel Novo Gravity Outlet UK6 UK8 UK10 UK12 Control Panel No 209102...
Страница 27: ...26 UK18 UK24 Control Panel No 209116...
Страница 28: ...27 UK30 UK36 UK42 UK50 Control Panel No 209111...
Страница 29: ...28 5 11 1 2 Tricel Novo Pumped Outlet UK6 UK8 UK10 UK12 UK18 UK24 Control Panel No 209101...
Страница 30: ...29 UK30 UK36 UK42 UK50 Control Panel No 209112...
Страница 42: ...41 12 Terms conditions Subject to our standard terms and conditions which are available on request...
Страница 43: ...42...