23
5.10
Non-standard installations
5.10.1
Alternative to concrete backfill (for wet sites without risers only)
•
The option of securing the Tricel Novo to a reinforced concrete slab or Deadman anchor
by way of straps may also be used, as shown below:
•
Tricel accepts no responsibility for the design of the concrete slab/Deadman anchor.
This solution should be designed by an on-site structural engineer to suit site
conditions.
•
Position the straps as close to the bolted joints as possible.
•
Install the reinforced concrete slab/ Deadman anchor after lowering the level of the
ground water, if necessary.
•
Once the straps have secured the Tricel Novo, the backfilling with concrete or gravel
can commence.
5.10.2
Sloping ground
When the slope of the ground is 5% or more, it is recommended to install a retaining wall to protect
the tank from the lateral thrust. Concrete backfill may also in some cases be sufficient to protect the
tank. A qualified structural engineer must determine if a retaining wall is required in the presence of a
steep slope as shown in the picture below:
5.10.3
Proximity to rolling & static loads
Minimum separation distances from:
•
Rolling Loads (e.g., vehicle traffic): 4 metres
•
Static Loads (e.g., dwelling house, shed): 3 metres
If installing the tank in an area where traffic or other superimposed loadings can be applied,
consult a structural engineer for the design of a reinforced concrete slab to prevent the
transmission of the load to the tank (or its concrete surround). If this slab is constructed
Содержание Novo UK10
Страница 1: ...0 106 Rev 11 Dec 2017 Tricel Novo UK6 50 Wastewater Treatment Plants Engineering a green future...
Страница 4: ...3...
Страница 5: ...4...
Страница 10: ...9...
Страница 11: ...10...
Страница 26: ...25 5 11 1 Electrical Diagrams 5 11 1 1 Tricel Novo Gravity Outlet UK6 UK8 UK10 UK12 Control Panel No 209102...
Страница 27: ...26 UK18 UK24 Control Panel No 209116...
Страница 28: ...27 UK30 UK36 UK42 UK50 Control Panel No 209111...
Страница 29: ...28 5 11 1 2 Tricel Novo Pumped Outlet UK6 UK8 UK10 UK12 UK18 UK24 Control Panel No 209101...
Страница 30: ...29 UK30 UK36 UK42 UK50 Control Panel No 209112...
Страница 42: ...41 12 Terms conditions Subject to our standard terms and conditions which are available on request...
Страница 43: ...42...