22
5.9
Risers
If a Tricel Novo requires a deeper than standard installation in order to align with the
wastewater outlet pipe from the dwelling, manhole risers are available to facilitate this and to
avoid the access hatch being positioned in a depression, as shown in the diagram:
Risers are available in the following sizes:
•
250mm (requires installation suitable for the site conditions)
•
500mm (requires a concrete backfill) *
•
750mm (requires a concrete backfill) *
* 500mm or 750mm risers cannot be retrofitted unless the correct installation is in place.
•
The Tricel Novo is suitable for a maximum manhole riser of 750mm which facilitates the
following maximum inlet inverts:
o
110mm Inlet: 1285mm
o
150mm Inlet: 1310mm
•
The Tricel Novo is not suitable where a deeper installation is required.
Important:
•
Never place the access covers below ground level.
•
Only use Tricel manhole access covers.
•
Do not allow ground water or storm water to enter the Tricel Novo.
Содержание Novo UK10
Страница 1: ...0 106 Rev 11 Dec 2017 Tricel Novo UK6 50 Wastewater Treatment Plants Engineering a green future...
Страница 4: ...3...
Страница 5: ...4...
Страница 10: ...9...
Страница 11: ...10...
Страница 26: ...25 5 11 1 Electrical Diagrams 5 11 1 1 Tricel Novo Gravity Outlet UK6 UK8 UK10 UK12 Control Panel No 209102...
Страница 27: ...26 UK18 UK24 Control Panel No 209116...
Страница 28: ...27 UK30 UK36 UK42 UK50 Control Panel No 209111...
Страница 29: ...28 5 11 1 2 Tricel Novo Pumped Outlet UK6 UK8 UK10 UK12 UK18 UK24 Control Panel No 209101...
Страница 30: ...29 UK30 UK36 UK42 UK50 Control Panel No 209112...
Страница 42: ...41 12 Terms conditions Subject to our standard terms and conditions which are available on request...
Страница 43: ...42...