Triax TOM 011 Скачать руководство пользователя страница 4

 
 

 

Mode d’emploi / 

User manual    TOM 011   

                                                                     

 13 / 18

 

 

Mesureur Puissance Optique 

Optical Power Meter 

TOM 011 

 Référence / Part Number: 307967 

 
 
 
 

1.

 

 Function 

5.1 Function Instructions 

(1)      

       

 Power Supply Switch: 

Press it to turn on or off the unit Auto Shut Off 

Selection: Press this key shortly to turn on or off the 

auto shut off function. Under this situation, the unit 

will automatically shut off after ten minutes idle time. 

 

(2

˅

         

Ā¬ā

 Wavelength Selection

˖

 

Press this key to switch the wavelength and display 

it on the top left of the LCD screen. 

(3

˅

       

Ā

dBm/W

ā

  Press this key to switch 

between the absolute measurement and relative measurement of the   

ptical power. 

(4

˅

       

Ā

REF

ā

  Press this key for a few seconds to store the current 

power value as the reference value which will be displayed on the top left of 

the LCD screen. Press this key shortly to enter the relative measurement 

mode and the reference value will be displayed on the top left of the LCD 

screen. It will compare the current power with the reference power and show 

the relative power value in dB. 
 
 

 

 

 

 

Содержание TOM 011

Страница 1: ...Optical Power Meter TOM 011 R f rence Part Number 307967 Contents 11 Overview 11 12 Main Features 11 13 Specifications 12 14 Standard Packages 12 15 Function 13 16 Operation and Notes 14 17 Maintenanc...

Страница 2: ...surement range accurate test self calibrating function and universal connector The stability and reliability of this power meter are greatly improved with the large square 1 0mm detector 12 Features z...

Страница 3: ...850 1300 1310 1490 1550 1625 Resolution dB 0 01 Optical Connector FC PC and SC APC Power Supply Alkaline Battery 3 AA 1 5V batteries AC Adaptor 9V Battery Operating Time 140 h with 1 5V Battery 3pcs O...

Страница 4: ...ngth Selection Press this key to switch the wavelength and display it on the top left of the LCD screen 3 dBm W Press this key to switch between the absolute measurement and relative measurement of th...

Страница 5: ...when using the battery The capacity in the mark will decrease with battery power Please replace the battery when the mark is empty 3 The auto off mark is showed on the bottom screen The auto off funct...

Страница 6: ...ss the dBm w key once to decrease the current power by 0 05dB which will be displayed on the LCD screen K Press key to switch the working wavelength L Press ON OFF key shortly to store the self calibr...

Страница 7: ...it on Low battery power or the battery is put wrongly 1 Replace the battery 2 Re put the battery Optical power is not stable after the unit turned off Use it after 15 minutes warm up 5 Notice 9 1 Ensu...

Страница 8: ...the repair or replace will not be higher than purchasing price of this unit 10 2 If the problems occurred can not be solved by the trouble shooting methods please contact us or the local distributor...

Страница 9: ...011 18 18 Mesureur Puissance Optique Optical Power Meter TOM 011 R f rence Part Number 307967 e mail sc triax fr Internet www triax com Mode d emploi du TOM 011 Version 1 0 Novembre 2011 TOM 011 Noti...

Отзывы: