2
TMU 5/9/17x3 C
Before you Install
©
The Triax TMU Single Cable Multi Switch family provides state
-
of
-
the
-
art switching technology for
both legacy
-
and SCR
-
(Single Cable Router) type satellite receivers.
The capability of each attached satellite receiver is automatically detected by the multi switch and
compatible ‘Legacy mode’ or ‘SCR Mode’ signals are transmitted accordingly.
The Triax TMU Single Cable Multi Switches are ideal for appartment buildings requiring multi
-
room
signal transmission. Up to three SCR capable satellite receivers can be connected per output port on
the TMU multi switch. Uniform signal
-
level distribution to each attached satellite
receiver is ensured through built
-
in automatic AGC functionality.
Automatic Legacy/SCR output switching
4/8/16 satellite polarity inputs (1, 2 and 4 satellite positions)
1 x passive terrestrial input
4 or 8 subscriber outputs
Auto Legacy setting = one satellite receiver (STB) per subscriber output line
Auto SCR setting = 3 x SCR satellite receivers (STB) per subscriber output line
Wide satellite input level range (60 to 91 dB
μ
V)
High output power (AGC controlled)
Supports satellite receivers with auto tuning
Low trunk throughloss
Multi standard DiSEqC support (Legacy/EN50494/EN50607/BSkyB)
DC input for LNB powering (TMU unit itself is powered via STBs)
Product Items: 1 SAT position: 307340, TMU
543 C and 307344, TMU 583 C
Product Items: 2 SAT positions: 307348, TMU
943 C and 307352, TMU 983 C
Product Items: 4 SAT positions: 307356, TMU
1743 C and 307360, TMU 1783 C
NOTE: It is NOT possible to connect both a Legacy STB AND an SCR STB on the same cable!
Connecting up to 3 x SCR STBs on same subscriber output cable is possible using either TAPs,
SPLITters or Loopthrough type Outlets. These must support DC pass through.
To prevent fire, short circuit or shock hazard:
Do not expose the unit to rain or moisture.
Install the unit in a dry location without infiltration or condensation of water.
Do not expose it to dripping or splashing.
Do not place objects filled with liquids, such as vases, on the units.
If any liquid should accidentally fall into the cabinet, disconnect the power plug.
To avoid any risk of overheating:
Install the unit in a well aired location and keep a minimum of 15 cm around the ap-
paratus for sufficient ventilation.
Do not place any items such as newspapers, table
-
cloths, curtains, etc. on the unit
that might cover the ventilation holes.
The unit must not be exposed to any source of heat (sun, heater, etc.).
Do not place any naked flame sources, such as lighted candles, on the apparatus.
Do not install the product in a dusty place.
Use the apparatus only in moderate climates (not in tropical climates).
Respect the minimum and maximum temperature specifications.
1
. Introduktion
2. Features
3. Before You
install read this
Triax A/S