8
technical Data
type
GNS 20
GNS 30
order No.
339120
339130
Frequency range
Input 1 - UHF (1)
MHz
470...862
470...862
Input 2 - VHF III
MHz
174...230
174...230
Input 3 - VHF I
MHz
-
47...68
- UHF (2)
MHz
-
-
Input 4 - FM
MHz
47...68 and
-
- VHF I
MHz
87,5...108
87,5...108
option: input 1 and input 2
combined with jumper
MHz
470...862 and
470...862 and
174...230
174...230
Gain *
Input 1 - UHF (1)
dB
22
31
Input 2 - VHF III
dB
20
30
Input 3 - VHF I
dB
-
30
- UHF (2)
dB
-
-
Input 4 - FM / VHF I
dB
20
30
Level controller
at all inputs
dB
0...-20
0...-20
Noise figure *
Input 1 - UHF (1)
dB
4
4
Input 2 - VHF III
dB
4
4
Input 3 - VHF I
dB
-
4
- UHF (2)
dB
-
-
Input 4 - FM / VHF I
dB
4
4
output level, iMR = 60 dB *
IMR 3 acc. EN 50083-5
dBµV
113
115
IMR 2 acc. EN 50083-3
dBµV
102
105
Power supply
Supply voltage (50 - 60 Hz)
V~
230 ±10%
230 ±10%
Power consumption
W
3,5
6
Ambient conditions acc. EN 60065
Operating temperatur range
°C
–25 … +55
–25 … +55
Degree of protection
II, isolated guard
II, isolated guard
Protection class
IP 20
IP 20
MTBF (Belcore @ 25°C)
h
300.000
300.000
housing
Weight
kg
ca. 0.68
ca. 0.68
Dimensions W x H x D
mm
150 x 80 x 50
150 x 80 x 50
HF connections 75
O
F connectors
F connectors
Screening
acc. EN 50083-2
class A
class A
*
Level controller 0 dB
tRiAX A/S
Bjørnkærvej 3
DK-8783 Hornsyld
Phone: +45 76 822 200