- 9 -
CCS-2 2001
3.2 emC
regul ations
To comply with the current EMC regulations, it is necessary to connect the lines
leading in and out of the head-end station using cable terminals.
When mounting the cassette in a head-end station which is installed in a 19"
cabinet, make sure the connections leading in and out for the 19" cabinet are
made using cable terminals.
CLASS
KLASSE
The attenuation of shielding of the connection lines for antenna must meet the
requirements for "Class A".
• Insert the required number of cable terminals in the openings provided in
the head-end station or in the 19" cabinet.
Tighten the nuts of the cable terminals until the teeth on the lock washers put under
have penetrated the exterior coating and a good connection is made between the
housing / 19" cabinet and cable terminals.