- 32 -
CCE 210
6
Final procedures
After installing the head-end station, upgrading accessories or installing cas-
settes it is necessary to tighten all cable connections, cable terminals and cover
screws in order to maintain compliance with current EMC regulations securely.
• Securely tighten the cable bolted connections using an appropriate open-
ended spanner.
• Mount the front cover (see assembly instructions of the head-end station).
6.1 Combination with other cassettes
- The transport stream provided at the ASI output can be transferred via the
ASI input of a following cassette to a modulator. If no signal is supplied
at the tuner inputs of this cassette, the following settings must be made for
INROUTE and OUTROUTE:
For example cassette CCS-2 1000:
At INROUTE setting "A+ASI=1 B+ASI=2" OUTROUTE must be set to
"1=>ASI
ASI=>MA
" or "2=>ASI
ASI=>MB
".
or
at INROUTE setting "A+B+ASI=1 ASI=2" OUTROUTE must be set to
"1=>ASI
ASI=>MA
".