background image

5

GB

Troubleshooting guide

Problem

Possible root cause

Solution

Weak or missing signal 
-check LED on power supply 
(PSU)

NO light indicates no voltage.
Often this is coursed by a short 
or a missing connection in the 
coax-cable or the cable con-
nectors

Remove the cable from the 
PSU, if the LED goes ON, 
there is a short in the cable. 
Then repair or replace the 
cable. 
If the LED is still off replace 
the PSU.

Weak or missing signal 
-check LED on power supply 
(PSU)
-check LED on UFO 

NO light indicates no voltage.
Often this is coursed by a short 
or a missing connection in the 
coax-cable or the cable con-
nectors 

If the LED is ON at the PSU, 
there is probably a missing 
connection in the cable or 
connectors.
Repair or replace.

Interference; herring-bone pat-
tern or  white horizontal stripes 
in the picture.

Interference is often caused by 
different electronic equipment 
- mobile phones, computers 
or transmitters -being used in 
close proximity to the UFO.

Increase the distance – in-
crease the height of the UFO

Ghosting; double pictures

Ghosting is caused by the TV 
signal being reflected from 
buildings, large ships etc.

Changing position a few 
meters, will often solve the 
problem.

Содержание 120

Страница 1: ...1 GB UFO 100 120 digital antenna Mounting instructions GB TRIAX your ultimate connection 891020A ...

Страница 2: ...2 GB UFO 100 120 digital antenna Connection cable and assembly Mount UFO on base Ensure that the UFO shells are fully mated with the bracket A Push forward B Push down Secure with enclosed screws ...

Страница 3: ...cal or horizontal surface Positioning the antenna Assemble brackets and desk mount Positioning the antenna and mark off holes for fixing Prepare the plastic base for mounting of U clamp for mast bracket M in 8 0 m m Mounting on mast ...

Страница 4: ...ting with centre mount UFO 120 digital Positioning the antenna Centre mounting bracket and deckmount Position the antenna and mark off holes for fixing Positioned antenna and counter nut fixed Mounting with universal mount UFO 120 digital ...

Страница 5: ...t indicates no voltage Often this is coursed by a short or a missing connection in the coax cable or the cable con nectors If the LED is ON at the PSU there is probably a missing connection in the cable or connectors Repair or replace Interference herring bone pat tern or white horizontal stripes in the picture Interference is often caused by different electronic equipment mobile phones computers ...

Страница 6: ...6 GB UFO 100 120 digital antenna Application examples IFP 529 12 V 5 V ...

Страница 7: ...28 Noise figure dB 2 5 2 5 Max output voltage dBµV 108 108 Supply voltage V 5 24 5 24 Power consumption mA 50 50 Dimensions length width height mm mm mm 325 255 65 325 255 65 Connector F connectors F connectors Included Mast bracket Ø25 60 Plastic base Mast bracket Ø25 60 Plastic base Universal mount Centre mount Plastic base Art No 133220 Mast bracket Ø25 60 Art No 133223 Universal mount Art No 1...

Страница 8: ...onfirms that the product conforms to relevant EEC harmonized standards and consequently can carry CE mark Relevant harmonized standards EN 50083 and EN 60065 06 2009 TRIAX your ultimate connection 891020A A product of the TRIAX group Dealer ...

Отзывы: