TriangleTube MAXI-FLO MF-135 Скачать руководство пользователя страница 2

Table of Contents

i

PRODUCT  & SAFETY INFORMATION
INSTALLATION

Code Compliance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Locating the Maxi-Flo Heat Exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Automatic Chlorinators and Chemical Feeders. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Operating Restrictions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

General Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Recommended Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Maxi-Flo Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Water Chemistry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4

Corrosion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Water Chemistry Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Start up Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Spring and Fall Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Winterizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Periodical Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Recommended Piping Schematic

MF-135, MF-200, MF-260 & MF-400 . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Recommended Piping Schematic 

MF-80, MF-135T, MF-260T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Pool Piping connection MF-135T and MF-260T only. . . . . . . . . . . . . . . . 7

SPECIFICATIONS & DIMENSIONS

MAXI-FLO

®

Stainless Steel Heat Exchanger. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

MAXI-FLO

®

Titanium Heat Exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Following  terms  are  used  to  bring  attention  to  the

presence of various risk levels or to important infor-

mation concerning product life.

Indicates  presence  of  a  hazard  which  will  cause

severe personal injury, death or substantial prop-

erty damage if ignored.

Indicates the presence of a hazard which can cause

severe personal injury, death or substantial prop-

erty damage if ignored.

Indicates  the  presence  of  a  hazard  which  will  or

can  cause  minor  personal  injury  or  damage  if

ignored.

Indicates special instructions on installation, oper-

ation or maintenance which are important but not

related to personal injury hazards.

DANGER

WARNING

NOTICE

CAUTION

Содержание MAXI-FLO MF-135

Страница 1: ...st be filed immediately against the transportation company by the consignee Leave all documentation received with owner for future reference STAINLESS STEEL AND TITANIUM HEAT EXCHANGER FOR SWIMMING PO...

Страница 2: ...T only 7 SPECIFICATIONS DIMENSIONS MAXI FLO Stainless Steel Heat Exchanger 8 MAXI FLO Titanium Heat Exchanger 9 Following terms are used to bring attention to the presence of various risk levels or to...

Страница 3: ...ture in excess of 104 F is considered unsafe for all persons Lower water temperatures are recommended for extended use exceeding 10 15 minutes and for all young children b Since excessive water temper...

Страница 4: ...tors must feed downstream of the unit and have an anti siphoning device to prevent chemical back up into the heat exchanger when the pump is shut off WARNING High chemical concentrations from improper...

Страница 5: ...ction See Fig 4 page 7 RECOMMENDED TEMPERATURE Swimming pool water temperature of 80 F US Swimming Rules and Regulations require pools for competition water temperature must be at 78 to 80 F Spa and t...

Страница 6: ...system until the water reaches the desired temperature setting WARNING SPRING AND FALL OPERATION During cold periods those above freezing weather maintain a minimum temperature setting 65 F to 70 F f...

Страница 7: ...ng From the pool Stainless Steel or CPVC Chlorinator 1 Maxi Flo Heat Exchanger 2 Boiler 3 Boiler Water Circuit 4 Sensor or Aquastat 5 Isolation Valve 6 Check Valve 7 Circulators 9 Filtration 10 Pump 1...

Страница 8: ...in Valve 16 Flow Control Valve 17 Check Valve Anti siphon Device Fig 2 Recommended Piping Schematic MF 80 MF 135T MF 260T 5 17 1 12 5 5 13 4 5 9 10 5 13 14 6 115V To the pool Heating zones return Heat...

Страница 9: ...ple Rubber Coupling MF 135T or MF 260T Heat Exchanger FIG 4 POOL PIPING CONNECTION MF 135T AND MF 260T ONLY Flow Switch Typ McDonnell Miller FS4 3 FIG 3 FIELD WIRING Note Recommend pipe thread sealant...

Страница 10: ...400 55 65 77 93 3 95 000 6 2 7 MF 80 77 6 5 6 8 Model No A B C D E F Weight lb 5 1 2 13 1 2 18 3 4 23 3 4 41 3 4 5 1 8 5 1 8 5 1 8 5 1 8 5 1 2 5 1 2 5 1 2 1 1 1 2 1 1 2 2 1 1 2 MF 135 MF 200 MF 260 M...

Страница 11: ...Ft Cold Water Flow Heat Transfer Surface Sq Ft 135 000 260 000 9 24 2 3 11 13 MF 135T MF 260T 92 92 5 6 Model No A B C D E F Weight lb 20 29 1 2 5 5 5 1 2 5 1 2 11 2 11 2 MF 135T MF 260T 4 1 4 4 1 4...

Страница 12: ...0 Forest Parkway Suite 100 West Deptford NJ 08066 Tel 856 228 8881 Fax 856 228 3584 E mail sales triangletube acv com For domestic water snow melting radiant floor refrigera tion Plates made of stainl...