background image

Module replacement Instructions

1.  Turn the power to the unit OFF by disconnect-

ing the main power source.

ELECTRICAL  SHOCK  HAZARD.    The
ON/OFF switch of the boiler does not discon-
nect  electrical  power  to  the  module.
Disconnect    electrical  power  to  the  boiler
using the main service switch.

2. Remove the front jacket panel by loosening the

retaining screws on each side of the display.

3. Dismount the front jacket panel by pulling the

bottom of the front panel out and the entire front
jacket panel down.

4. Pull the Control Display Module tray out from

the  bottom  jacket  panel  and  swing  the  tray
downward.  The guide pins on the tray should
disengage the bottom panel (Fig.2).

Before  proceeding  to  the  following  steps
mark and label all connections and location
of the connections prior to disconnecting any
wire connections.

5. Disconnect  all  molex  plugs  from  the  module.

The two white molex plugs  and one grey molex
plug have locking levers that need to be disen-
gaged prior to disconnection.

6. Disconnect the (4) ground wires from the mod-

ule.  Use care not to damage the wire terminals.

7. To remove the module from the tray, disengage

the  rear  retaining  tabs  of  the  module  from  the
tray  sides  by  carefully  pulling  the  tray  sides
slightly outward.

8. Once the retaining tabs are disengaged slide the

module  back  and  upward  away  from  the  face
plate of the tray.

Do  not  discard  the  module  if  a  warranty
claim  is  being  submitted.    Contact  Triangle
Tube  Customer  Service  for  information
regarding the warranty period of the module
and if a RGA number is needed to return the
damaged module. If the control was shipped
with  a  RETURN  SHIPPING  LABEL,  send
module directly back to Triangle Tube.

NOTICE

WARNING

NOTICE

CHALLENGER 

Control Display

Module

Replacement Kit 

2

Fig. 2: Removal of control module

Fig. 1: Loosening of retained screws