DESCRIPTION

The HEAT BUSTER is a high volume fan 

designed for heavy-duty use in factories, ware-

houses, laundries, garages, etc. The unit is 

constructed of cold-rolled steel with a powder 

coat finish. Guards are made of steel wire and 

comply with OSHA guarding requirements. 

GENERAL SAFETY INFORMATION

1.

 Your HEAT BUSTER fan will operate only on 

115 Volt AC, 60Hz (cycle) current with a mini-

mum of a 15 Amp circuit.

2.

 

WARNING:

 To reduce the risk of elec-

tric shock, 

DO

 

NOT

 expose to water or 

rain. To guard against electric shock while the 

fan is connected to power source, 

DO  NOT 

PERMIT

 fan to come in contact with other 

grounded objects such as pipes, radiators, 

ranges, etc.

3. DO NOT ABUSE POWER CORD. DO 

NOT

 pull on cord to remove from electrical 

receptacle. Keep cord away from heat, oil and 

sharp edges. Inspect cord periodically and 

replace if damaged.

4.

 Disconnect the fan when not in use, before 

servicing and cleaning and when repairing or 

replacing parts.

5.

 

DO NOT

 carry or move the fan when con-

nected to power source. 

6.

 When the HEAT BUSTER is used out-of-

doors with extension cord, use only cord of 

proper size (Amp rating), UL listed and with 

receptacle to accept three prong grounded plug 

furnished on the fans power cord. Only round 

jacketed extension cords should be used.

7.

 Before operating this fan, check for worn 

or damaged parts and replace or repair as 

required. To avoid risk of fire, electrical shock 

or other injury, disconnect from power source 

before servicing.

8.  DO  NOT 

operate the HEAT BUSTER near 

flammable liquids or in gaseous or explosive 

atmospheres as sparks from motor may ignite 

fumes.

9.

 If the wire guards are removed, replace 

before normal operation.

ASSEMBLY

No assembly required 

INSTALLATION

Simply locate fan in desired position, connect 

power cord, and fan is ready for operation.

IMPORTANT:

 READ INSTRUCTIONS CAREFULLY BEFORE  ATTEMPTING  

TO  INSTALL, OPERATE OR SERVICE THIS FAN. FAILURE TO COMPLY  WITH  

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY 

DAMAGE. RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.

    

SYMPTOM

1. Defective motor
2. No power

Fan does not operate

1. Replace motor
2. Check to see if power cord 

is plugged in. Check fuse or 

circuit breaker.

POSSIBLE CAUSE(S)

CORRECTIvE ACTION

1. Loose pulleys or fan blade
2. Intake guard or exhaust 

guard excessively dirty

1. Tighten pulley set screw
2. Clean guards

Insufficient air flow

1. Replace motor
2. Replace bearings and seals
3. Move motor to tighten belt

1. Defective motor bearings
2. Defective fan bearings
3. Worn belt

Squealing, slapping or whining 

noises while operating

MINOR AND ROUTINE

1. Motor bearings are pre-lubricated ball 

bearings. Re-lubrication is not required.

2. Keep guards and blade clean by 

vacuuming or wiping periodically. Also 

keep motor from accumulating excessive 

dust that may cause overheating.

 

DISASSEMBLY PROCEDURE

1. Disconnect cord from power supply.

2. Remove guard screws.

3. Remove Guard.

NOTE: Upon completion of maintenance, 

reinstall components in reverse order as 

indicated above.

 

  

WHEN ORDERING REPAIR PARTS

always give the following information:

1. Part description

2. Model Number of fan

3. Serial number

        

MAINTENANCE

TROUBLESHOOTING

WARNING: Disconnect power before servicing

WARNING:

TO REDUCE THE RISK OF FIRE OR 

ELECTRICAL SHOCK DO NOT USE 

THIS FAN WITH ANY SOLID STATE 

FAN SPEED CONTROL DEvICE.