8. SERVICING
I
MPORTANT: ISOLATE ELECTRICAL SUPPLY TO THE
BOILER BEFORE SERVICING
To maintain the boilers high thermal efficiency and reliable
operation, it should be serviced annually by a qualified
engineer preferably OFTEC trained and registered.
Electrical work should be carried out by a qualified
engineer.
Note:
It is a requirement of the boiler’s guarantee that an
annual service is carried out by a qualified engineer.
If the boiler is used to provide central heating and hot
water all year round, the best time for its annual service is
just before the start of the heating season. Where the
boiler is shut down for the summer months, the service
should be carried out as soon as possible after the end of
the heating season.
Oil tank
Open drain-cock to draw off any accumulated water and
sludge.
Line filters
Turn off oil supply and remove filter bowl. Wash filter ele-
ment clean with kerosene.
Servicing the Burner
See separate leaflet ‘Burner Details’.
Servicing the Boiler
(Burner removed)
1.
Remove the flue-cover and lift out flue-baffles (See
diagram below).
2. Brush all deposits from flue-baffles and internal surfaces
of the boiler.
3. Remove flue deposits from the combustion chamber
floor using a vacuum cleaner.
4. Replace flue baffles in the correct arrangement (See
diagram below for order of assembly). Refit the flue-
cover and fully tighten wing-nuts to make a gas tight
seal.
5. Refit burner to boiler, connect flexible air hose
(balanced flue boilers only) and plug-in burner lead.
6. Turn on oil supply, switch on electricity and burner
should fire.
7. Finally check the combustion readings with those given
under ‘Burner Settings’ and make any air or pressure
adjustments necessary.
Fig 22a
Combi 65 Baffle Arrangement
Combi 90 Baffle Arrangement
PART No. 221651
1-OFF
PART No. 221650
5-OFF
PART No.
208838
3-OFF
PART No.
208834
1-OFF
Содержание Combi 50 ECO
Страница 10: ...7 Fig 2...
Страница 11: ...8 Fig 3 Note When fitting a room thermostat remove link wire A and wire the thermostat into terminals T and H...
Страница 14: ...11 Fig 4 EUROSTAR COMBI SCHEMATIC LAYOUT Fig 5 SEALED SYSTEM PIPING SCHEMATIC DIAGRAM...
Страница 15: ...12 Fig 6 ALTERNATIVE METHODS OF FILLING A SEALED SYSTEM Fig 7 TYPICAL DISCHARGE PIPE ARRANGEMENT...
Страница 20: ...17 Fig 11 SINGLE PIPE OIL SUPPLY HEAD H METRES...
Страница 21: ...18 Fig 12 TWO PIPE OIL SUPPLY...
Страница 22: ...19 Fig 13 DE AERATED OIL SUPPLY INSTALLATION...
Страница 26: ...23 727mm 727mm 100 125 780mm Fig 17 MODEL 70 90 7 175mm MIN 18 455mm MAX MODEL 70 90 23 585mm MIN 33 850mm MAX...
Страница 32: ...29 Fig 20 2273 VERTICAL B F KIT 2273 Vertical Balanced Flue Kit 600mm 24 3000mm MAX 118...