Triad RF Systems, Inc. Confidential
Page 4
2.
Initial
Radio
Configuration
Below is an outline of recommended settings for the Silvus SC4200, to be set
prior
to
connecting to the Triad RF Systems BDA.
2.1
Frequency
Set the radio operating frequency within the range of the Triad BDA frequency range.
Consult specification sheet for frequency details.
2.2
Data Link Distance
Set the data link distance to desired or expected operating distance.
2.3
BDA Support Setting
In the SC4200 graphical interface there will be a tab near the top of the menu labelled “BDA
Support.” Clicking this tab will present the option to enable Auto Noise Estimation and the
option to select between Basic mode and No PA next to “PA Mode.” Auto Noise Estimation
is not required unless the Rx gain of the BDA is unknown.
Please select the option “Basic Mode” and enter the Tx and Rx gain of your amplifier in the
corresponding text fields that become available (test data is sent when purchasing your BDA
from Triad). Then, enter the desired output power in the following text field, and click Apply.
This will enable the Tx/Rx control line on the Silvus Radio.
Before powering on the radio, ensure that the RF ports are properly
terminated, or connected to their antennae. Operating the unit with the RF
ports open can cause damage to the radio.