![TRI tool 040921 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/tri-tool/040921/040921_manual_1159569010.webp)
10
TRI TOOL INC.
92-1173 : Orig. 040921
MAINTENANCE
All components should be cleaned and coated with a light film of oil prior to use.
Use a clean, non-detergent oil, preferably SAE 10 (90 SSU) or lighter or oil as
specified for the air motor.
Air Supply for the BOILERMASTER™ with an air motor requires an adequate filter/
regulator/lubricator (FRL) to be used.
A maximum of 90 PSI (621 kPa) line pressure is recommended.
NOTE:
NOTE:
The Motor warranty is void if damage occurs from contaminated air or lack of
lubrication.
If the BOILERMASTER™ is operated in the vertical position, cutting head up,
it should be turned upside down and the chips and/or other debris removed
after each bevel has been completed.
Tool life may be severely shortened, unless chips and/or other debris that
have been deposited on the cutting head during the machining operations are
removed.