WIRING DIAGRAM

ELECTRIC DEFROST - 115V

FAN

MTR

FAN

MTR

FAN

MTR

DATA PLATE FOR 

MOTOR QUANTITY

   EVAPORATOR 

REFER TO

EVAPORATOR

FAN MOTOR 

POWER PLUGS

RD

DEFROST TERMINATION

FD-FAN DELAY

DT-DEFROST TERM

& FAN DELAY

(10.0A MAX.)

CONTROL

FD

BK

FAN MOTOR 

POWER PLUGS

REFER TO

DATA PLATE FOR 

MOTOR QUANTITY

EVAPORATOR

MTR

MTR

MTR

FAN

FAN

FAN

(10.0A MAX.)

DT-DEFROST TERM
FD-FAN DELAY

& FAN DELAY

CONTROL

DEFROST TERMINATION

FD

BK

   EVAPORATOR 

PARAGON # 8145

MUST BE MADE

EVAP FIELD MODIFICATION

WARNING

SEE NOTE: 

SPACE

GND.

F

4

DT

BN

C

X

3

N

H1

H3

H2

ORANGE JUMPER

THERMOSTAT

NOTE #4

SWITCH

(IF USED)

PUMP DOWN

NOTE #4

SOL VALVE

1

N.C.

LIQUID LINE

BREAKER

(IF USED)

COMPR INTERLOCK

1

2

N

NAMEPLATE FOR ELECTRICAL

REFER TO EVAPORATOR

GND

REQUIREMENTS

3

4

TM

X

FUSE OR

CIRCUIT

PARAGON # 8145

DEFROST CLOCK

OR EQUIVALENT

15A

N

L1

N.C.

LIQUID LINE

SOL VALVE

NOTE #4

GND.

3

N

X

4

F

DT

BN

RD

C

FROM H2 TO N

REMOVE ORANGE JUMPER

(IF USED)

SWITCH

PUMP DOWN

NOTE #4

H2

H3

H1

SPACE

THERMOSTAT

(IF USED)

COMPR INTERLOCK

OR EQUIVALENT

1

CIRCUIT

4

2

3

X

N

NOTE #3

BREAKER

TM

FUSE OR

DEFROST HEATER

L1

C

T1

CONTACTOR

CIRCUIT

BREAKER

NOTE #3

N

GND

L1

FUSE OR

USING MAXIMUM 15A HEATER OVERCURRENT PROTECTION

   FOR ALL MODELS WITHOUT DEFROST HEATER CONTACTOR

   FOR ALL MODELS USING DEFROST HEATER CONTACTOR

REFER TO EVAPORATOR

DEFROST CLOCK

REQUIREMENTS

NAMEPLATE FOR ELECTRICAL

FAN MODELS ONLY)

(SUPPLIED ON MULTIPLE

TERMINAL BOARD

BK

BK

 DEFROST HEATERS

BOTTOM

BK

BOTTOM

L.H. COIL

BK

R.H. COIL

ORANGE
JUMPER

 DEFROST HEATERS

L.H. COIL

BOTTOM

BK

R.H. COIL

BOTTOM

BK

BK

BK

ORANGE
JUMPER

T2

L2

ORANGE JUMPER

1

SEE NOTE: 

TERMINAL BOARD

(SUPPLIED ON MULTIPLE

FAN MODELS ONLY)

DEFROST HEATERS MUST NOT EXCEED 

4.) MAY BE FACTORY INSTALLED-MOUNTED

MAXIMUM VALUE SHOWN ON 

EVAPORATOR NAMEPLATE.

EVAPORATOR FAN MOTORS AND 

AND WIRED ON EVAPORATOR

1). USE COPPER CONDUCTORS ONLY

3). OVERCURRENT PROTECTION FOR

2). USE 75°C WIRE (OR HIGHER)

NOTES

FACTORY WIRING

OPTIONAL FACTORY

WIRING BY OTHERS

OR BY OTHERS

ALL FIELD WIRING MUST BE DONE IN 

COMPLIANCE WITH ALL APPLICABLE LOCAL 

AND NATIONAL CODES.

TERMINALS

 -TERMINAL BLOCK TERMINAL

 -COMPONENT TERMINAL 

CONDUCTORS/WIRING

2-TL ED1   03/08

(IF APPLIC.)

TTL

60Hz

23/06/17

T30-TTL-PDI-16

- 7 -

Содержание TTL Series

Страница 1: ...Resources Service Parts Troubleshooting Warranty etc 15 As Built Service Parts List BACK High Medium and Low Temperature Applications 10 F 23 3 C or Above Box Temperature TTL Two Way Low Profile Evapo...

Страница 2: ...rage space Dual refrigeration coils and two way air distribution reduces air velocities to minimize product dehydration Air enters through fan and discharges two ways out of each coil side Rugged heav...

Страница 3: ...448 554 739 870 1372 1741 2611 R404A R507 850 1250 1700 2100 2800 3300 5200 6600 9900 249 366 498 615 821 967 1524 1934 2901 R22 810 1190 1620 2000 2700 3100 4900 6300 9400 237 348 473 584 780 919 144...

Страница 4: ...1 2 1 5 15 70 0 65 0 81 15 60 530 4 6 5 8 15 021LE S1A 1 1 2 1 5 15 70 0 65 0 81 15 60 530 4 6 5 8 15 028LE S1A 1 1 2 1 5 15 70 0 65 0 81 15 60 0 60 0 75 15 30 750 6 5 8 2 15 033LE S1A 1 1 2 1 5 15 70...

Страница 5: ...15ME S2A 1 0 7 0 9 15 60 0 24 0 30 15 50 530 2 3 2 9 15 020ME S2A 1 0 7 0 9 15 60 0 24 0 30 15 50 530 2 3 2 9 15 025ME S2A 1 0 7 0 9 15 60 0 24 0 30 15 50 530 2 3 2 9 15 032ME S2A 1 0 7 0 9 15 60 0 24...

Страница 6: ...ER PLUGS REFER TO EVAPORATOR DATA PLATE FOR MOTOR QUANTITY MTR FAN TERMINALS MTR FAN MTR FAN SOLENOID VALVE EVAPORATOR NOTE 4 SPACE THERMOSTAT N C NOTE 4 LIQUID LINE 4 GND F FAN MOTOR POWER PLUGS REFE...

Страница 7: ...OR EQUIVALENT 1 CIRCUIT 4 2 3 X N NOTE 3 BREAKER TM FUSE OR DEFROST HEATER L1 C T1 CONTACTOR CIRCUIT BREAKER NOTE 3 N GND L1 FUSE OR USING MAXIMUM 15A HEATER OVERCURRENT PROTECTION FOR ALL MODELS WIT...

Страница 8: ...WIRING DIAGRAM ELECTRIC DEFROST 230V TTL 60Hz 23 06 17 T30 TTL PDI 16 8...

Страница 9: ...8 7 8 479 4 1 2 114 14 1 8 359 17 3 4 451 9 3 4 248 12 6 5 7 020M 3 8 1 2 Flare 18 7 8 479 5 1 2 140 14 1 8 359 17 3 4 451 9 3 4 248 13 7 6 2 025M 3 8 1 2 Flare 18 7 8 479 5 1 2 140 14 1 8 359 17 3 4...

Страница 10: ...F 23 5 8 600 C 7 5 8 194 23 3 4 603 DIMENSIONAL DATA 2 3 FAN Inches mm MODEL TTL Suc Conn TXV C D E F APPROX WEIGHT ID Sweat Inlet Size Inches mm Inches mm Inches mm Inches mm Lbs Kgs 060M 1 2 1 2 ODS...

Страница 11: ...LL TXV Selections based on 90 100 F liquid MODEL TTL TD R404A R507 R448A R407A R407C R22 010M 10 HF 1 8 SC HF 1 4 HC 15 015M 10 HF 1 8 SC HF 1 4 HC 15 020M 10 HF 1 8 SC HF 1 4 HC 15 HF 1 4 SC 025M 10...

Страница 12: ...595 20 3 135 4 940 6 270 9 405 RECOMMENDED EXPANSION VALVE SELECTION MEDIUM TEMPERATURE MODELS SPORLAN R404A MODEL TTL 009L 013L 017L 021L 028L BTUH VALVE BTUH VALVE BTUH VALVE BTUH VALVE BTUH VALVE E...

Страница 13: ...laws LOCATION The evaporator is designed to be mounted to the ceiling of the box or cabinet Refrigeration piping and electrical connections are routed to the rear sides through the knock outs The uni...

Страница 14: ...ost models AD Multiple fans have a junction terminal box for conduit connections INSTALLATION INSTRUCTIONS CONT D When fan delay thermostats are installed the fans may not start up until the coil temp...

Страница 15: ...ng t rp com call 1 844 893 3222 x529 web t rp com parts email parts t rp com call 1 844 893 3222 x501 email orders t rp com call 1 844 893 3222 x501 email shipping t rp com call 1 844 893 3222 x503 TT...

Страница 16: ...the manufacturer s policy of continuous product improvement we reserve the right to make changes without notice NATIONAL REFRIGERATION AIR CONDITIONING CANADA CORP 159 Roy Blvd Brantford Ontario Canad...

Отзывы: