Before You Begin
Introduction
It is important to be aware of the information listed below before installing your Trenton modular blade
server. System performance may be affected by incorrect usage of these features.
External Power Source – Redundant 900w Power Supply Version
Incoming AC power must be supplied to both of the power supply receptacles located at the rear of the chassis.
These dual AC power connections ensure that the active system power supply; as well as the stand-by/fail-over
supply, is each connected to a power source with a solid earth ground, and each supply must have an incoming
power source of: 100-127/200-240VAC, 10A/5A at 50 to 60Hz.
Chassis Airflow
When installing the chassis, ensure that a minimum free air space is available around the system. The installation
should have a minimum of 4-6 inches (101-152mm) behind the chassis and 7-8 inches
(178-203mm) in front of the chassis. Any front cabinet doors or access aisles must accommodate a MBT8301 front
chassis clearance of at least 7.0” (178mm) in order to provide proper clearance for the fan FRU replacement.
Ideally, a chassis clearance of 0.5-1.5 inches (13-38mm) above the system is desirable
C
HASSIS
P
LACEMENT
The MBT8301 system is designed with ruggedness in mind, however, precautions should be observed to ensure safe
and reliable performance. Place the chassis on a flat, stable surface capable of supporting both the system weight
and any anticipated peripherals. Installation area should be secure and free from danger of liquid or airborne
contaminants that could damage internal components as well as supporting all airflow requirements.
.