Before You Begin 

I

NTRODUCTION

 

It is important to be aware of the information listed below before installing your Trenton rackmount 
computer.  System performance may be affected by incorrect usage of these features. 

 

E

XTERNAL 

P

OWER 

S

OURCE 

 

Incoming AC power must be supplied to each receptacle located at the rear of the chassis.

  

This AC power 

receptacle must be connected to a power source with a solid earth ground, and capable of delivering 110-
240VAC at 50 to 60Hz.  The typical maximum current draw of the rackmount computer is 4.07A per 
incoming power receptacle. 

 
I

NTERNAL 

5V

 

C

URRENT 

L

IMIT

 

The maximum current limits for the +5V, +3.3V and +12V outputs from the system power supply are 32A, 
32A and 65A respectively.  The system’s power monitoring circuits will shut the system down if these 
maximum current limits are drawn from the power supply. 
 
 

C

HASSIS 

A

IRFLOW

 

When installing the chassis, ensure that a minimum free air space is available around the system.  The 
installation should have a minimum of 4-6 inches (101-152mm) behind the chassis and 7-8 inches  
(178-203mm) in front of the chassis.  Any front cabinet doors or access aisles must accommodate a 
THS2085 front chassis clearance of at least 7.0” (178mm) in order to provide proper clearance for the 
chassis’ front door, front panel I/O port connections and to gain access to the system air filter for 
maintenance.  Ideally, a chassis clearance of 0.5-1.5 inches (13-38mm) above the system is desirable, but 
not required. 

 
C

HASSIS 

R

ACK 

M

OUNTING

 

The THS2085 system can be installed in a rackmount cabinet that conforms to EIA standards for computer 
equipment with 19-inch wide panels.  The cabinet must be tall enough to accommodate the computer’s 
height and deep enough to accommodate the system’s depth, while providing the proper clearances for air 
flow and cabling.  A cabinet with a standard depth of 31.5 inches (800mm) will provide the suggested 
minimum rear chassis clearances needed for an installation.  
  
 

Содержание HDEC Series

Страница 1: ...THS2085 HDEC Series 2U RACKMOUNT COMPUTER No THS2085 xxx Revision A INSTALLATION GUIDE Publication No 8402085 03396...

Страница 2: ...ailure is caused by accident acts of God or other causes beyond the control of Trenton Trenton reserves the right to make changes or improvements in any product without incurring any obligation to sim...

Страница 3: ...s associated with any particular installation Trenton Systems cannot assume responsibility or liability for actual system use based on the examples and diagrams No patent liability is assumed by Trent...

Страница 4: ...R 2 SYSTEM DIMENSIONS LAYOUT 2 1 SYSTEM DIMENSIONS 2 1 CHAPTER 3 INSTALLATION INSTRUCTIONS 3 1 ENVIRONMENTAL CONSIDERATIONS 3 1 RACK MOUNTING 3 1 RACKMOUNT INSTRUCTIONS 3 1 SLIDE RAIL INSTALLATION 3 1...

Страница 5: ...ques when moving and installing the system When removing or installing boards and sub components keep these components in their static shielded bag and or packaging until you are ready to for componen...

Страница 6: ...S AIRFLOW When installing the chassis ensure that a minimum free air space is available around the system The installation should have a minimum of 4 6 inches 101 152mm behind the chassis and 7 8 inch...

Страница 7: ...and power supply combination System Model Number Backplane Model SHB Model Number Description of Backplane SHB and System Power Supply Combination THS2085 000 HDB8227 HEP8225 Backplane 1 SHB Slot and...

Страница 8: ...im Line R W DVD 4 67CFM system fans Consult with Trenton for available storage drives and optical media drives compatible with the THS2085 SHB BATTERY CAUTION Risk of explosion if the system host boar...

Страница 9: ...al clearance PCI Express option card slot locations THS2085 001 Rear View 2U Fixed mount Power Supply Configuration Front View THS2085 002 Rear View 1U Removable Power Supply Configuration 19 0 48 3cm...

Страница 10: ......

Страница 11: ...ACKMOUNT INSTRUCTIONS A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient There...

Страница 12: ...are bag number S 047 0 includes 10 mounting rail to computer chassis screws 1 mounting hardware bag number S 017 1 includes 36 rail frame to 19 rack mounting screws 10 nuts 10 flat washer 2 Take one o...

Страница 13: ...il mounting hardware 9 The rubber bumper on the outside portion of slide rails are to be located toward the rear of the 19 rack 10 Refer to figure 3 and attach two rail frames each to the outside port...

Страница 14: ...he rackmount enclosure You should have another person help you lift and slide the chassis into the enclosure 17 You should hear and audible click when the rail stop hooks on the slide engage with the...

Страница 15: ...located at the rear of the system An over current protection device shall protect each power cord To connect AC power to the computer 1 Establish a chassis to earth ground connection to the THS2085 ch...

Страница 16: ......

Страница 17: ...THS2085 are designed for easy access Make sure you have a front chassis clearance of at least 6 152mm to remove or install system cards COOLING FANS The four 60mm cooling fans of the THS2085 are attac...

Страница 18: ...rrent limits for the 5V 3 3V and 12V outputs from the system power supply are 32A 32A and 65A respectively The system s power monitoring circuits will shut the system down if these maximum current lim...

Страница 19: ...for more details ELECTRICAL Line Voltage 110 240VAC Line Frequency 50 60Hz Power Consumption 450W typical 650W max PHYSICAL Approximate Dimensions W x H x D 19 x 3 5 x 18 2 48 3cm x 8 9cm x 46 2cm Ne...

Страница 20: ......

Страница 21: ...THS2085 Installation Guide 6 1 Trenton Systems Inc Chapter6 CertificationDocuments CE Certificate of Compliance...

Страница 22: ...THS2085 Installation Guide Trenton Systems Inc 6 2 FCC Part 15 Subpart B Certificate of Compliance...

Отзывы: