© Copyright 2016 TRENDnet. All Rights Reserved.
TRENDnet User’s Guide
TFC‐1600MM
17
Redundant Backup Setting
COMMANDS
show
mediaconverter redundant
config mediaconverter
redundantgrp
<integer (1‐8)> ([{enable|disable}] [restart])
The redundant function is to change the master line to the slave line in case of the linking fails happen.
The Redundant functions were set fixed, the master slot is slot 1(odd number slot) and the slave slot is slot 2(even number slot), and there are eight redundant groups in all. The “Act”
will indicate what slot is active.
The redundant function depends only on some Smart Media Converters.
Redundant Backup Setting commands:
show
mediaconverter redundant: show master slot or slave slot is active.
config mediaconverter
redundantgrp
<integer (1‐8)> [restart]: When Master slot linking fails happen, slave slot will be enabling; user can process this command change the active slot
(slave slot) back to the master slot.
config mediaconverter
redundantgrp
<integer (1‐8)> [enable|diable]: There are eight redundant groups can be enable or disable when those Smart Media Converters support the
redundant function.
Configuration
COMMANDS
save config
System Function
COMMANDS
clear
show
command_history
logout
Содержание TFC-1600MM
Страница 1: ...TRENDnet User s Guide Cover Page ...
Страница 30: ......