Страница 1: ...TEG S4000i 4 Slot SNMP Modular Switch Ethernet Fast Ethernet Gigabit Ethernet User s Guide Version 2 0 23 April 2003 1...
Страница 2: ...h manual Update Version Progress status Remark QA PM 23 04 2003 V2 0 On checking 1 10 100 TX 48350 spec MAC 4K Buffer 256Kbytes 2 2 4 8 100FX 48310 spec MAC12k Buffer 5Mbytes 3 Gigabit module 48360 MA...
Страница 3: ...Content Introduction Product Overview Network Configuration Connecting to the Network Web Based Management SNMP Management Product Specifications Appendix A Internet Explorer Setting Appendix B VLAN S...
Страница 4: ...be achieved using 4 x 8 port 10 100 Base TX switch modules Modular Switch features store and forward switching scheme Every module has it s own entry MAC address table to store source address The back...
Страница 5: ...ont side Supports Half duplex mode for backpressure and full duplex for flow control Store and Forward switching architecture for abnormal packet filtering Up to 9 6Gbps Back plane forwarding rate Mac...
Страница 6: ...FTP MIB II and Private MIB supported IEEE 802 1p QoS ToS Port Security Management Methods The Modular Switch supports following management methods Console and Telnet Management Web based Management SN...
Страница 7: ...Network Management SNMP Simple Network Management Protocol provides a means to monitor and control network device and to manage configurations statistic collection performance and security Data is pa...
Страница 8: ...ordially Four Rubber Feet RS 232 cable User Guide Modular Switch Rubber Feet Rack mounted Kit RS 232 cable User Guide Power Cord Figure 1 2 Package Contents Compare the contents of your Modular Switch...
Страница 9: ...ur slots All optional models come with the built in CPU modules The LEDs are located on the front panel of the Switch to allow you to monitor the operation and performance at a glance All ports can be...
Страница 10: ...ions to other devices and networks are also on the front panels LED Status Meaning Power Green Power on Diag Red Alert and problem notice Green Device has been connected to the port Blinks The data is...
Страница 11: ...ot switch to other ports Spanning Tree Spanning Tree Protocol STP is an industry standard that prevents loops configurations in switched networks The Spanning Tree algorithm creates a single path thro...
Страница 12: ...multiple lower speed links than to underutilize a gigabit port Available copper links and supported distances are more pervasive for lower speed links For example 100Mbps NICs and switch ports are les...
Страница 13: ...any neighboring multicast switch to ensure that it will continue to receive the multicast service Port Security Port Security allow you to restrict specific MAC addresses to reside in some port The m...
Страница 14: ...1000Mbps Gigabit the switch is perfectly suited to an evolving network environment where demand for network speed is increasing Collapsed Backbone Application For small network where substantial grow...
Страница 15: ...ent users to connect to the corporate backbone The Modular Switch used as segment switch can alleviate user contention for bandwidth and eliminate server and network bottlenecks All ports can connect...
Страница 16: ...on NOTE Full duplex operation only applies to point to point access for example when attaching the switch to a workstation server or another switch When connecting to hubs use a standard cascaded conn...
Страница 17: ...forwarded within that VLAN VLAN allows the grouping of end stations logically based not on physical location but on business policies such as job function or department Members of a group can be dispe...
Страница 18: ...to switch connections It is also possible to have resources exist in multiple VLANs on one switch as shown in the following figure Figure 3 4 Shared Server In this example stations on different VLANs...
Страница 19: ...P cable with RJ 45 connector Check if the cable and connectors work properly Fiber cable with SC ST MT RJ VF 45 connector Check if the cable and connector types are correct A power outlet 100 to 240V...
Страница 20: ...clean smooth level and sturdy Make sure there is enough clearance around the Switch to allow attachment of cables power cord and air circulation Attaching Rubber Feet A Make sure mounting surface on...
Страница 21: ...bracket to align with the holes on one side of the switch and secure it with the bracket screws Then attach the remaining bracket to the other side of the Switch Figure 4 2 Figure 2 4 Attach mounting...
Страница 22: ...especially important for enclosed rack installations Power On After all network cables are connected plug the power cord into the power socket on the back panel and the other end into a power outlet...
Страница 23: ...k ACT LED turns on If the switch fails the self test the Diagnostic LED will blink Connecting the Switch The serial console port is a male DB 9 connector that enables a connection to a PC or terminal...
Страница 24: ...onsole port Baud Rate 9600 bps Start Bit 1 Data Bits 8 Stop Bit 1 Parity none Figure 4 5 The setting of communication parameters You can run Hyper Terminal or a terminal emulation program using the ab...
Страница 25: ...IP address Once you have logged into the switch you need to assign an IP address to the switch s Ethernet interfaces so that you can connect to the switch using a web browser Select Device settings fr...
Страница 26: ...0 Select Default Gateway on the Device page and enter the IP address of the default gateway if you are sending packets to another IP network and press Return Default Gateway is 192 168 16 254 Remembe...
Страница 27: ...a More function to choice after typing 1 or 2 b Pick any number you need to set up for example the option 2 is for the Full or Half mood setting 27...
Страница 28: ...de s MAC address table of system per module or per port that attached on the device Spanning Tree Protocol Spanning tree is a link management protocol that provides path redundancy while preventing un...
Страница 29: ...Broadcast Storm Filter IGMP Internet Group Multicasting Protocol IGMP is used to support real time applications such as video conferencing or streaming audio 29...
Страница 30: ...VLAN Mode 2 modes VLAN For Cpu 2 VLANs 30...
Страница 31: ...if device is installed in a internet environment switch may be attach by Hacker then the system maybe will crash for prevent this status you can enable the function and setting the IP address it prov...
Страница 32: ...net Explorer 5 0 and later versions It is based on Java Applets with an aim to reduce network bandwidth consumption enhance access speed and present an easy viewing screen Note By default IE4 0 does n...
Страница 33: ...w 3 The Password screen appears 4 Type user name and password The default is root for both 5 Press Enter or Click OK then the Home Screen of the Web based management appear System Configuration Figure...
Страница 34: ...IP address of the managed unit can be modified in IP Config page Subnet Mask The subnet mask of the managed unit can be modified in IP Config page Default Gateway The default gateway of the managed u...
Страница 35: ...nto the Switch Figure 5 3 The Modules Page Any four of the following modules can be installed to the Switch 8 port auto sensing 10 100Base TX Switch Module 2 port 100Base FX SC ST Fiber Module 4 port...
Страница 36: ...r transmitted from that port Link indicates whether a node links to that port or not Speed current receive or transmit speed of 10 100 1000 Mbps Duplex full or half duplex Tagged whether a packet tran...
Страница 37: ...ows 8 counters for each port in each module Module and Port number Bytes RX the total bytes received from that port Bytes TX the total bytes sent from that port Frames RX the total packets receives fr...
Страница 38: ...tatistics 2 The statistics 2 page displays the detailed packet size information about each port You can compare and evaluate throughput or other port parameters All screen data is updated automaticall...
Страница 39: ...he packet is tagged with non zero VLAN id field then this is used as the VLAN id Otherwise the default VLAN id of the input port is used You can assign a single switch port to two or more VLANs The fa...
Страница 40: ...button only once to configure the desired VLANs you want Note if you want to set multiple VLANs we suggest that you set Default VLAN ID for each port first in Ports page Trunk Port trunking is the abi...
Страница 41: ...es path redundancy while preventing undesirable loops in the network For Layer 2 Ethernet network to function properly only one active path must exist between two stations The spanning tree algorithm...
Страница 42: ...the root switch Root Hello Time how often the root switch broadcasts Hello message to other switches Root Forward Delay the amount of time a port will remain in the listening and learning states befo...
Страница 43: ...is 15 The Port Configuration describes those ports information in this switch in the spanning tree Priority the port priority The smaller this value the higher priority this port has Learning if you...
Страница 44: ...when you enable the spanning tree protocol because all ports in the switch will listen and learn you may lose communication to the switch you are managing Wait about 2 times forward delay 2 15 second...
Страница 45: ...t the number of MAC address to reside in a port you must do the following Click the Enable checkbox for that port IF the Enable checkbox is uncheck there is no MAC address count restriction for that p...
Страница 46: ...02 1q tag are assigned priority according to a flexible fixed for the old 48310 and 48320 module and programmable mapping of the 802 1p user priority tag 3 bits value from 0 to 7 to the internal prior...
Страница 47: ...c using this field This feature provides Quality of Service QoS IF this function of a port is enabled then the most significant 6 bits of the TOS these 6 bits are also known as the DiffServ Code Point...
Страница 48: ...st traffic If you want your switch to support multimedia and IP multicast enable this option default is enabled When this option is enabled this switch only directs the multicast data packets to the p...
Страница 49: ...ckets if it is moved to another port Static addresses are manually entered into the Static Address Table 1 Enter the MAC address in the MAC Address field ex 00 11 22 33 44 55 2 Select the Module and P...
Страница 50: ...is enabled if more than 3000 packets per second broadcast packets sent to a port lasts 5 seconds this port will not receive any broadcast packets until less than 3000 packets per second broadcast pac...
Страница 51: ...Mirror Source Port choice box in the corresponding mirror source module Only one port can be monitored in one module at the same time Choose the corresponding target module port in Mirror Target Modu...
Страница 52: ...dit box If you want to change the user name or password for the managed node the following steps is needed Click the Change Password checkbox Enter the user name in Username edit box Enter the same pa...
Страница 53: ...set the get request and set request community name you can type the desired text string in the corresponding edit box The default value of get request community is public The default value of set req...
Страница 54: ...age Save and Reboot Save You can save current settings by click the Current Settings checkbox then press the Apply button next to the checkbox You should reboot the system so that your current setting...
Страница 55: ...oot System checkbox then press the Apply button next to the checkbox Please wait a moment about 25 seconds then continue to operate this home page Figure 5 18 Save Reboot page Upgrade You can on line...
Страница 56: ...firmware please reboot the system so that the new firmware will take effect Note If you can t upgrade your new firmware successfully try again don t shut down the switch 6 SNMP Management This section...
Страница 57: ...B related queries being sent by the network management software The SNMP agent gathers data from the MIB which keeps information about device parameters and network data The agent can send traps or no...
Страница 58: ...ice GET RESPONSE The reply to a GET GETNEXT and SET commands sent by a SNMP agent TRAP A message sent by an SNMP agent to an SNMP manager indicating some event occurred Table 6 1 The commands of SNMP...
Страница 59: ...FD COL 2 LEDs Gigabit Fiber LK ACT FD COL 4 LEDs Gigabit Copper 1000M 100M LK ACT FD COL Per Unit Power Diag Network Cables 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100m 100Base TX 2 pair U...
Страница 60: ...midity 10 to 90 Non condensing Power Supply Input rate 100 240VAC 50 60Hz Internal universal power supply DC 3 3V 13A 5V 4A Power Consumption 33 45 Watt depended on modules EMI FCC Class A CE Mark Saf...
Страница 61: ...odify the browser setting to enable Java applets to use network ports We use Internet Explorer 5 0 as demonstrational sample We first select Internet Optional under Tools of function bar then follow t...
Страница 62: ...Step 3 click sites Step 4 add the IP of the Modular Switch to the zone click Add Step 5 Disable left bottom box Require server verification for all sites in this zone then click OK 62...
Страница 63: ...Step 6 go back to Internet Options then click Customer Level Step 7 pull down rolling to find Java Step 8 select Custom under Java 63...
Страница 64: ...Step 9 select Java Custom Setting Step 10 select Edit Permissions Step 11 select Enable under Unsigned Content 64...
Страница 65: ...ples will show you how to Configure VLAN Group Port Based VLAN The following example shows you how to create 2 Port based VLANs including two overlapping ports Work Station B File Server Work Station...
Страница 66: ...N Group you need to set PVID number on Ports page as below We set VLAN ID of Ports 1 4 1 and PVID of Ports 5 8 2 Remember to click Apply button after you finish your setting Then return to VLAN page a...
Страница 67: ...ethod of tagging is defined in the IEEE 802 1Q standard to configure switch port by the tagging function that allows the port to transmit tagging frame VLAN Tagging can only be used if the devices at...
Страница 68: ...set VLAN ID 1 2 3 as below Click the checkbox of Tagged on Module 1 port 1 which is a Gigabit port Remember to click Apply button after you finish your setting Then return to VLAN page you will see t...
Страница 69: ...rt 1 Module 1 Remember to click Apply button after you finish your setting Now you have finished one Tagging VLAN setting While you connect this Switch to another Modular Switch to form tagging VLAN r...
Страница 70: ...ease follow the Appendix A for troubleshooting Before contact your dealer network supplier or our service support write down these information on a paper for a better description Symptoms error messag...
Страница 71: ...und to be free of defects you will only be charged for testing and handling Technical Support TRENDware provides free technical support for customers worldwide for the duration of the product s warran...