Specifications 

Standards 

IEEE 802.3u 100Base-FX 
IEEE 802.3x, IEEE 802.1Q, IEEE  
PCI V2.1, 2.2 

Interface 

PCI/Multi-Mode SC-type port 

Performance 

148,810pps for 100Mbps 

Data Rate 

200Mbps (Full-Duplex) 

Cable 

62.5/125µm multi-mode SC-type fiber cable, up to 2 km, 
wavelength 1310nm 

LED Indicators 

LNK (Link) / ACT (Activity), 100 (100Mbps) 

Dimensions 

122mm × 117mm   (4.8 × 4.6in.) 

Net Weight 

80g (0.18lb.) approx.  

Power Consumption 

1W max. 

Operating Temperature 

0

°

C

 to 45

°

C

 (32

°

F

 to 113

°

F

Storage Temperature 

-10

°

C

 to 70

°

C

 (14

°

F

 to 158

°

F

Humidity 

5%-95% non-condensing 

Certifications 

CE, FCC 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание TE100-PCIFC

Страница 1: ...MicheM ...

Страница 2: ...r Adapter 11 Cabling Requirements 12 NIC CONTROL SET UTILITY 13 MY COMPUTER 13 NIC 13 Protocol 13 Service 14 Client 14 GENERAL 15 SETTING 16 STATISTICS 16 DIAGNOSTICS 17 WAKE UP PACKET 17 VLAN SETTINGS 18 Add Remove VLAN 18 Setting for add remove VLAN 18 VLAN01 VLAN ID 1 added 18 Driver setting changed by NIC Control Set 19 Remove VLAN Change VLAN property 20 DOS DIAGNOSTIC UTILITY 21 DIAG UTILITY...

Страница 3: ... the product package you shall find the items listed below Please inspect the contents and report any apparent damage or missing items immediately to our authorized reseller TE100 PCIFC Multi Language Quick Installation Guide CD ROM Driver User s Guide ...

Страница 4: ... Support Network Device Class Power Management Specification Version 1 0a Support Wake on LAN magic packet z MAC Enhancement Function IEEE 802 1q multiple VLAN with VLAN ID auto insertion extraction UDP TCP IP checksum offload for Ipv4 frames z Two LEDs LNK ACT link activity 100 100Mbps speed Driver Support The Adapter supports a wide range of drivers for commonly used network operating systems z ...

Страница 5: ...tic Utility LEDs c LNK ACT Link Activity d 100 100Mbps LEDs Status Indication LNK ACT Steady A valid network connection established LNK stands for LINK Flashing Transmitting or receiving data ACT stands for ACTIVITY Off Neither connection nor activity 100 Steady 100Mbps Off 10Mbps ...

Страница 6: ...lick Install Driver and then click your operating system Step 3 Click OK to finish the installation Step 5 Turn off the power to the PC Step 6 Remove any metal decorations from your hands and wrists Step 7 Remove the cover from your PC Step 8 Locate an empty non shared bus mastering PCI slot and remove the corresponding backplate Save the screw for use in Step 10 ...

Страница 7: ...hosen slot and press firmly with proper push to ensure it is fully seated in the slot Step 10 Secure the TE100 PCIFC with the screw you saved in step 8 Note If you wish to use the Remote Wake Up function please complete the installation in next section Connecting the Remote Wake Up Cable before proceeding to step 10 Step 11 Replace the PC cover Step 12 Proceed to Connecting to Your Network section...

Страница 8: ...arefully insert the TE100 PCIFC into the chosen slot and press firmly with proper push to ensure it is fully seated in the slot Step 7 Secure the TE100 PCIFC with the screw you saved in step 4 Note If you wish to use the Remote Wake Up function please complete the installation in next section Connecting the Remote Wake Up Cable before proceeding to step 7 Step 8 Replace the PC cover Step 9 Turn th...

Страница 9: ...9 Step 12 If the following screen pop up insert the Windows 98SE CD ROM into CD ROM driver For Windows 98SE only Step 13 Click OK to reboot your computer ...

Страница 10: ... cable For more detail information please check the User s Guide of your Motherboard Wake on LAN magic packet Step 1 Make sure the power to the PC is off Step 2 Check if the TE100 PCIFC is properly installed in a PCI slot Step 3 Prepare a Remote Wake Up cable Connect the cable from TE100 PCIFC to motherboard connector Step 4 Replace the PC cover Step 5 Proceed to Connecting to Your Network Section...

Страница 11: ...e to the connector on the Fiber Adapter This network cable consists of two individual cables one for transmission TX and the other for reception RX Step 4 Connect the other end of the network cable to a 100Base FX hub or a switch Note i Insert the cable that is connected to the transmit TX connector on the Fiber Adapter into the receive RX connector on the network hub or switch ii Insert the cable...

Страница 12: ...istance when connecting the TE100 PCIFC to your network please refer to the following table Fiber Connections Type Wavelength of 1300nm Fiber Optic required Max Distance full duplex SC Multi mode 62 5 125 µm 2 km Note The maximum node to node network distance is in full duplex operation ...

Страница 13: ...on It provides Network Interface Card information setting statistics and diagnostic function Also it provides multiple VLAN function My Computer NIC All NIC drivers are currently installed in this computer Protocol All network protocols are currently installed in this computer ...

Страница 14: ...14 Service All network services are currently installed in this computer Client All network clients are currently installed in this computer ...

Страница 15: ...15 General Display the basic information of the adapter such as MAC Address IP Address Link Speed and Duplex Mode ...

Страница 16: ...16 Setting Display and set the parameters of the adapter by disable enable the function Statistics Display all the statistics information of the NIC ...

Страница 17: ...pback and Cable Link The continuous option can be set as an infinite loop of testing Please be award that perform this task will temporary disable the adapter Once the adapter has finished the test it will enable again Wake up Packet Configure the Wake up packet type for Wake On LAN ...

Страница 18: ... VLAN settings Add Remove VLAN Setting for add remove VLAN User should specify VLAN ID and VLAN name in the dialog box VLAN01 VLAN ID 1 added VLAN01 VID 1 will be displayed in VLAN area in NIC Control Set ...

Страница 19: ...19 Driver setting changed by NIC Control Set NIC Control Set will enable 802 1Q Tagging automatically if VLAN is created ...

Страница 20: ...20 Remove VLAN Change VLAN property ...

Страница 21: ...ed z Interrupt Output Line Interrupt is assigned by PCI BIOS and cannot be modified z Connection Type The physical media type currently had connected z Boot ROM Size Select Boot ROM size for 8K 16K 32K 64K FlashROM or No Boot ROM Boot ROM base address is assigned by PCI BIOS and cannot be modified Functions Key z F1 Help screen z F4 Change boot ROM size z F5 Diagnose this network adapter z F6 Netw...

Страница 22: ...n2000 Windows XP Windows 2003 server Workgroups 3 11 Windows NT 3 51 and 4 0 LAN Manager LANtastic PC NFS Novell Netware 3 11 3 12 4 x 5 x 6 0 Client 32 Linux Kernel 2 2 x 2 4 x 2 6 x FreeBSD 3 2 4 0 4 11 4 2 5 x SCO UnixWare 7 x OpenUnix 8 SCO UNIX 5 0 Find the suitable network driver for the platform that you are using Carefully read the readme text file for that driver ...

Страница 23: ...200Mbps Full Duplex Cable 62 5 125µm multi mode SC type fiber cable up to 2 km wavelength 1310nm LED Indicators LNK Link ACT Activity 100 100Mbps Dimensions 122mm 117mm 4 8 4 6in Net Weight 80g 0 18lb approx Power Consumption 1W max Operating Temperature 0 C to 45 C 32 F to 113 F Storage Temperature 10 C to 70 C 14 F to 158 F Humidity 5 95 non condensing Certifications CE FCC ...

Страница 24: ...tained in stored on or integrated with any products returned to TRENDnet pursuant to any warranty There are no user serviceable parts inside the product Do not remove or attempt to service the product by any unauthorized service center This warranty is voided if i the product has been modified or repaired by any unauthorized service center ii the product was subject to accident abuse or improper u...

Страница 25: ...TESTING UNAUTHORIZED ATTEMPTS TO REPAIR OR MODIFY OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING OR OTHER HAZARD LIMITATION OF LIABILITY TO THE FULL EXTENT ALLOWED BY LAW TRENDNET ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ...

Страница 26: ...ccess to the GPL Code or LGPL Code These codes are distributed WITHOUT WARRANTY and are subject to the copyrights of the developers TRENDnet does not provide technical support for these codes Please go to http www gnu org licenses gpl txt or http www gnu org licenses lgpl txt for specific terms of each license PWP05202009v2 ...

Страница 27: ...27 ...

Отзывы: